A large-scale multicentre study of patient skin doses in interventional cardiology: dose-area product action levels and dose reference levels.

نویسندگان

  • E Bogaert
  • K Bacher
  • K Lemmens
  • M Carlier
  • W Desmet
  • X De Wagter
  • D Djian
  • C Hanet
  • G Heyndrickx
  • V Legrand
  • Y Taeymans
  • H Thierens
چکیده

For 318 patients in 8 different Belgian hospitals, the entire skin-dose distribution was mapped using a grid of 70 thermoluminescence dosimeters per patient, allowing an accurate determination of the maximum skin dose (MSD). Dose-area product (DAP) values, exposure parameters and geometry, together with procedure, patient and cardiologist characteristics, were also registered. Procedures were divided into two groups: diagnostic procedures (coronary angiography) and therapeutic procedures (dilatation, stent, combined procedures (e.g. coronary angiography + dilatation + stent)). The mean value of the MSD was 0.310 Gy for diagnostic and 0.699 Gy for therapeutic procedures. The most critical projection for receiving the MSD is the LAO90 (left anterior oblique) geometry. In 3% of cases, the MSD exceeded the 2 Gy dose threshold for deterministic effects. Action levels in terms of DAP values as the basis for a strategy for follow-up of patients for deterministic radiation skin effects were derived from measured MSD and cumulative DAP values. Two DAP action levels are proposed. A first DAP action level of 125 Gy cm(2) corresponding to the dose threshold of 2 Gy would imply an optional radiopathological follow-up depending on the cardiologist's decision. A second DAP action level of 250 Gy cm(2) corresponding to the 3 Gy skin dose would imply a systematic follow-up. Dose reference levels - 71.3 Gy cm(2) for diagnostic and 106.0 Gy cm(2) for therapeutic procedures - were derived from the 75 percentile of the DAP distributions. As a conclusion, we propose that total DAP is registered in patient's record file, as it can serve to improve the follow-up of patients for radiation-induced skin injuries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment.

In this paper, a large-scale multicentre patient dose study performed in eight Belgian interventional cardiology departments is presented. Effective dose (E) was calculated based on a detailed dose-area product (DAP)-registration during each procedure and by using conversion coefficients generated by the Monte Carlo-based computer program PCXMC. Conversion coefficients were found to be 0.177 mS...

متن کامل

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

متن کامل

The need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography

Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...

متن کامل

Proposal of reference levels for cardiac interventional procedures. An European Coordination Action

Interventional cardiology is a medical specialty widely known to deliver high radiation dose to patients, who may receive, in some complex cases, skin doses over the threshold for deterministic effects. Because several studies have demonstrated large variability in delivered doses, European SENTINEL consortium has carried out a patient dose survey to propose regional Reference Levels (RL) as a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 82 976  شماره 

صفحات  -

تاریخ انتشار 2009