Through-slice dephasing for eddy current artifact reduction in bSSFP
نویسندگان
چکیده
Eddy current effects can severely degrade image quality when using balanced steady-state free precession imaging with rapidly varying phase encode ordering schemes, which have common use in cardiac cine MRI. In this work, we explore and characterize a previouslyproposed technique, through-slice dephasing, as the sole technique for eddy current artifact removal. We demonstrate that artifacts vary for different slice orientations yet they can be removed using the herein investigated technique.
منابع مشابه
Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)
Purpose To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in 2π dephasing...
متن کاملEffects from RF spoiling disequilibrium in the background offsets of phase-contrast velocity imaging
Background Phase-contrast imaging normally uses gradient-echoes with RF spoiling and phase-encode rewinding with a fixed dephasing by gradient “spoiler” pulses in each TR (time between RF pulses) studied in detail (1) where effective artifact suppression in magnitude images required >≈ 8PI dephasing over the slice thickness, with >≈ 2PI dephasing over an FE pixel. However, the effectiveness of ...
متن کاملCAIPIRINHA-accelerated 2D bSSFP imaging with improved banding behavior using Gradient-Controlled Local Larmor Frequency (GC-LOLA)
Background Cardiac MRI often requires a careful trade-off between SNR, spatio-temporal resolution and slice coverage. Providing fast acquisitions, high SNR and flow/motion robustness, bSSFP has become the dominant sequence. Drawbacks are high SAR levels and sensitivity to B0 inhomogeneities. For improving slice coverage, MSCAIPIRINHA [1] has emerged as a standard method. By simultaneously scann...
متن کاملEddy current-induced artifact reduction in spiral trajectory balanced-SSFP for transition-band SSFP fMRI
J. Lee, J. M. Pauly Electrical Engineering, Stanford University, Stanford, CA, United States Introduction Balanced SSFP is known to be very sensitive to any magnetization disturbance since all gradients are fully refocused in every TR and the phase accrual between RF pulses solely comes from offresonance precession. One of the major sources for this magnetization disturbance is eddy currents th...
متن کاملArtifact-free and multi-contrast SSFP imaging achieved in a single acquisition
Introduction Balanced SSFP (bSSFP) is a pulse sequence with great clinical potential because of its short scan time, high SNR, and lower SAR (specific absorption rate). However, due to its sensitivity to field inhomogeneities, SSFP imaging is always degraded by the banding artifact [1]. Although the banding artifact may be reduced with improved shimming and shortened repetition time (TR), it ca...