Fabrication of anodically electrodeposited iridium oxide film pH microelectrodes for microenvironmental studies.

نویسندگان

  • Achintya N Bezbaruah
  • Tian C Zhang
چکیده

A new method for fabrication of anodically electrodeposited iridium oxide film pH microelectrodes has been developed in this study. Novel for its tip size (3-10-microm tip diameter), the microelectrode is fabricated in a tapered glass micropipet filled with a low melting point alloy. The tapered end is recessed and platinized. Thereafter, iridium oxide is electrodeposited over the platinized end in the recessed part. The microelectrode has a very short response time (t80 < 5 s) in the pH range of 0-12 with an accuracy of 0.05 pH unit. The pH microelectrode is not affected by most ions and complexing agents of relevance in environmental and biological studies; it can be used in fluids over wide ranges of stirring speeds (0-55 rpm) and temperatures (approximately 5-40 degrees C). Redox agents such as dissolved oxygen and hydrogen peroxide have no effect on the pH response while quinhydrone, ferro- and ferricyanide, and sodium sulfide have marked effects. However, the microelectrode can still be used in any sample when calibration is done in standards having similar redox characteristics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemically deposited iridium oxide reference electrode integrated with an electroenzymatic glutamate sensor on a multi-electrode array microprobe.

An implantable micromachined multi-electrode array (MEA) microprobe modified for utilization as a complete electrochemical biosensor for rapid glutamate detection is described. A post-fabrication method for electrochemical deposition of an iridium oxide (IrOx) film onto a designated microelectrode enabled incorporation of an IrOx reference electrode (RE) on the microprobe. The on-probe IrOx RE ...

متن کامل

Measurements of the capacitance and the response time of solid-state potentiometric sensors by an electrochemical time-of-flight method

A micro-electrochemical time-of-flight technique relying on galvanostatic ion generation and potentiometric sensing (P-ETOF) has been developed in order to characterize dynamic properties of solid-state potentiometric sensors and to measure their capacitance. Lithographically-fabricated generator-sensor devices featuring 10 lm-wide micro-electrodes spaced by 20– 50 lm are used in either an open...

متن کامل

Fabrication of a needle-type pH sensor by selective electrodeposition

This manuscript reports on the development of a needle-type sensor for in situ on-site measurement of pH. Conventional pH microelectrode sensors are fabricated by pulling glass pipettes and applying ion-selective films at the tip. However, these sensors suffer from low fabrication yields and short sensor lifetime due to disruption or loss of the ion-selective membrane after repeated use. The de...

متن کامل

A pH Electrode Based on Melt-Oxidized Iridium Oxide

Fabrication and characterization of a novel potentiometric pH electrode based on melt-oxidized iridium oxide film is presented. The oxide film produced in a lithium carbonate melt has the composition of LixIrOy•nH2O, and shows high chemical stability. The electrode based on this oxide film exhibits very promising pH sensing performance, with an ideal Nernstian response in the tested pH range of...

متن کامل

Fabrication of a Miniature Multi-Parameter Sensor Chip for Water Quality Assessment

Water contamination is a main inducement of human diseases. It is an important step to monitor the water quality in the water distribution system. Due to the features of large size, high cost, and complicated structure of traditional water determination sensors and devices, it is difficult to realize real-time water monitoring on a large scale. In this paper, we present a multi-parameter sensor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 22  شماره 

صفحات  -

تاریخ انتشار 2002