Venous haemodynamics of Jet Impulse Technology within a lower limb fibreglass cast: a randomized controlled trial
نویسندگان
چکیده
OBJECTIVES We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. DESIGN Randomized controlled trial. PARTICIPANTS Twenty-four healthy participants aged 18-54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. SETTING Pacific Radiology, Lower Hutt, Wellington. MAIN OUTCOME MEASURES The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. RESULTS The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was -0.8 (-6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. CONCLUSION In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility.
منابع مشابه
Cohort feasibility study of an intermittent pneumatic compression device within a below-knee cast for the prevention of venous thromboembolism
OBJECTIVES To determine the likely enrolment rate of eligible participants into a randomised controlled trial (RCT) in which a within-cast intermittent pneumatic compression device using Jet Impulse Technology (IPC/JIT) is 1 of 3 possible interventions in a RCT for the prevention of venous thromboembolism (VTE) in the clinical setting of isolated lower limb cast immobilisation. DESIGN A prosp...
متن کاملVascular Impulse Technology versus elevation in the treatment of posttraumatic swelling of extremity fractures: study protocol for a randomized controlled trial
BACKGROUND Fractures of the extremities are often complicated by a variable degree of swelling secondary to hemorrhage and soft tissue injury. Patients typically require up to 7 days of inpatient bed rest and elevation to reduce swelling to an acceptable level for operative treatment with internal fixation. Alternatively, an intermittent pneumatic compression device, such as the Vascular Impuls...
متن کاملLow molecular weight heparin for prevention of venous thromboembolism in patients with lower-limb immobilization.
BACKGROUND Immobilization of the lower limb is a risk factor for venous thromboembolism (VTE). Low molecular weight heparins (LMWHs) are anticoagulants, which might be used in adult patients with lower-limb immobilization to prevent deep venous thrombosis (DVT) and its complications. This is an update of the review first published in 2008. OBJECTIVES To assess the effectiveness of low molecul...
متن کاملP-228: Low Dose HCG Adjunct to r-hFSH/GnRH Antagonist for Controlled Ovarian Stimulation in Assisted Reproductive Technology: A Prospective and Randomized Trial
Background: Deep suppression of LH in GnRH antagonist cycles may have detrimental effect on reproductive out come. It was hypnotized that adding LH activity via the administration of low dose HCG in late follicular phase shortened the duration of stimulation, decreased consumption of gonadotropin and increased estrogen levels. This study was designed to evaluate the effect of adding low dose HC...
متن کاملاثرات یک دوره برنامه تمرینی اصلاحی بر مؤلفههای نیروی عکسالعمل زمین طی دویدن در کودکان دارای زانوی پرانتزی: یک مطالعه کارآزمایی
Background and Objectives: Genu varum is one of the lower limb malalignments that is associated with changes in the lower limb biomechanics during walking and running. The selected corrective program has the least complications for children. Therefore the purpose of the present study was to investigate the effects of a period of corrective exercise training program on the running ground reactio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2017