Estimation of Daily Energy Expenditure in Pregnant and Non-Pregnant Women Using a Wrist-Worn Tri-Axial Accelerometer

نویسندگان

  • Vincent T. van Hees
  • Frida Renström
  • Antony Wright
  • Anna Gradmark
  • Michael Catt
  • Kong Y. Chen
  • Marie Löf
  • Les Bluck
  • Jeremy Pomeroy
  • Nicholas J. Wareham
  • Ulf Ekelund
  • Søren Brage
  • Paul W. Franks
چکیده

BACKGROUND Few studies have compared the validity of objective measures of physical activity energy expenditure (PAEE) in pregnant and non-pregnant women. PAEE is commonly estimated with accelerometers attached to the hip or waist, but little is known about the validity and participant acceptability of wrist attachment. The objectives of the current study were to assess the validity of a simple summary measure derived from a wrist-worn accelerometer (GENEA, Unilever Discover, UK) to estimate PAEE in pregnant and non-pregnant women, and to evaluate participant acceptability. METHODS Non-pregnant (N = 73) and pregnant (N = 35) Swedish women (aged 20-35 yrs) wore the accelerometer on their wrist for 10 days during which total energy expenditure (TEE) was assessed using doubly-labelled water. PAEE was calculated as 0.9×TEE-REE. British participants (N = 99; aged 22-65 yrs) wore accelerometers on their non-dominant wrist and hip for seven days and were asked to score the acceptability of monitor placement (scored 1 [least] through 10 [most] acceptable). RESULTS There was no significant correlation between body weight and PAEE. In non-pregnant women, acceleration explained 24% of the variation in PAEE, which decreased to 19% in leave-one-out cross-validation. In pregnant women, acceleration explained 11% of the variation in PAEE, which was not significant in leave-one-out cross-validation. Median (IQR) acceptability of wrist and hip placement was 9(8-10) and 9(7-10), respectively; there was a within-individual difference of 0.47 (p<.001). CONCLUSIONS A simple summary measure derived from a wrist-worn tri-axial accelerometer adds significantly to the prediction of energy expenditure in non-pregnant women and is scored acceptable by participants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimates of energy expenditure using the RT3 accelerometer in patients with systemic lupus erythematosus

This study aimed to characterize energy expenditure patterns using the tri-axial accelerometer and to identify the association of energy expenditure with clinical parameters in patients with systemic lupus erythematosus (SLE). Estimates of energy expenditures represented by total activity calorie (TA), physical activity calorie (PA), total activity calorie per body weight (TABW), and physical a...

متن کامل

How accurate is triaxial RT 3 TM ( RT 3 ) accelerometer for estimating energy expenditure ?

The participants are instructed to remove the RT3 only for sleeping, bathing and swimming activities but some studies have shown the participants remove the accelerometer for longer times. The activities performed while the accelerometer is not being worn and, or energy that was not recorded during this time has never been estimated. This study aimed to assess compliance in using the accelerome...

متن کامل

Estimating activity-related energy expenditure under sedentary conditions using a tri-axial seismic accelerometer.

Activity-related energy expenditure (AEE) is difficult to quantify, especially under sedentary conditions. Here, a model was developed using the detected type of physical activity (PA) and movement intensity (MI), based on a tri-axial seismic accelerometer (DynaPort MiniMod; McRoberts B.V., The Hague, the Netherlands), with energy expenditure for PA as a reference. The relation between AEE (J/m...

متن کامل

Comparison of Nutrients Intake among Pregnant Anemic & Non-Anemic Women

Background: Anemia, interpreted as a low blood hemoglobin values, was considered as a major health complication in the world.  However, anemia in pregnancy is a global public health problem in the developing countries, posing high risk of adverse results for expecting mothers as well as their fetus. The aim of study was to compare nutrientschr('39') intake among pregnant anemic & non-anemic wom...

متن کامل

Validity and Comparability of a Wrist-Worn Accelerometer in Children.

BACKGROUND: Wrist-worn accelerometers may provide an alternative to hip-worn monitors for assessing physical activity as they are easier to wear and may thus facilitate long-term recordings. The present study aimed at a) assessing the validity of the Actiwatch (wrist-worn) for estimating energy expenditure b) determine cut-off values for light, moderate and vigorous activities, c) studying the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011