3D Corneal Shape After Implantation of a Biosynthetic Corneal Stromal Substitute.
نویسندگان
چکیده
PURPOSE The current and projected shortage of transplantable human donor corneas has prompted the development of long-term alternatives to human donor tissue for corneal replacement. The biosynthetic stromal substitutes (BSS) characterized herein represent a potentially safe alternative to donor organ transplantation for anterior corneal stromal diseases. The goal of this phase 1 safety study was to characterize the three-dimensional (3D) corneal shape of the first 10 human patients implanted with a BSS and assess its stability over time. METHODS Ten patients underwent anterior lamellar keratoplasty using a biosynthetic corneal stromal implant for either advanced keratoconus or central corneal scarring. Surgeries were performed at Linköping University Hospital, between October and November 2007. Serial corneal topographies were performed on all eyes up to a 4-year follow-up when possible. Three-dimensional shape average maps were constructed for the 10 BSS corneas and for 10 healthy controls. Average 3D shape corneal elevation maps, difference maps, and statistics maps were generated. RESULTS The biosynthetic stromal substitutes implants remained stably integrated into the host corneas over the 4-year follow-up period, without signs of wound dehiscence or implant extrusion. The biosynthetic stromal substitutes corneas showed steeper surface curvatures and were more irregular than the healthy controls. CONCLUSIONS Corneal astigmatism and surface steepness were observed 4 years after BSS implantation, while the implants remained stably integrated in the host corneas. Future studies will indicate if biomaterials technology will allow for the optimization of postoperative surface irregularity after anterior stromal replacement, a new window of opportunity that is not available with traditional corneal transplantation techniques.
منابع مشابه
Prediction of Corneal Condition After Corneal Ring Implantation in Keratoconus Patients
Background: Keratoconus is a common complication among corneal defects. As a result of expeditious and extensive progress of medical science in recent decades, corneal ring implantation has turned into a successful surgical procedure to correct the vision of Keratoconus patients; however, selecting the right patient is essential in the success of the operation. The prediction of corneal conditi...
متن کاملInnervation of tissue-engineered recombinant human collagen-based corneal substitutes: a comparative in vivo confocal microscopy study.
PURPOSE To compare reinnervation in recombinant human collagen-based corneal substitutes with allografts during a 1-year postimplantation follow-up period in pigs. A retrospective comparison to innervation in porcine collagen-based biosynthetic grafts was also performed. METHODS Pigs received a corneal allograft or a substitute made of either recombinant human type-I or -III collagen. In vivo...
متن کاملA biosynthetic alternative to human donor tissue for inducing corneal regeneration: 24-month follow-up of a phase 1 clinical study.
Corneas from human donors are used to replace damaged tissue and treat corneal blindness, but there is a severe worldwide shortage of donor corneas. We conducted a phase 1 clinical study in which biosynthetic mimics of corneal extracellular matrix were implanted to replace the pathologic anterior cornea of 10 patients who had significant vision loss, with the aim of facilitating endogenous tiss...
متن کاملA Cornea Substitute Derived from Fish Scale: 6-Month Followup on Rabbit Model
A fish scale-derived cornea substitute (Biocornea) is proposed as an alternative for human donor corneal tissue. We adopt a regenerative medicine approach to design a primary alternative to the use of fish scale for restoring sight by corneal replacement. Biocornea with corneal multilayer arrangement collagen was implanted to rabbits by pocket implantation. Our study demonstrated the safety and...
متن کاملبررسی اصلاح قوز قرنیه با استفاده از قطعات حلقوی داخل قرنیهای فرارا
Background and Objective: Evaluation of the results, safety, and stability of ferrara intracorneal ring segment (FICRS) implantation for Keratoconus correction (age range was 24.39±8.32 years). Materials and Methods: In this clinical trial study, 64 eyes of 57 patients with keratoconus and clear cornea that had FICRS implantation were studied. Uncorrected visual acuity (UCVA), best-spectacl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 57 6 شماره
صفحات -
تاریخ انتشار 2016