"Detachment of the carinal hook following endobronchial intubation with a double lumen tube"

نویسندگان

  • Ana C Rocha
  • Mafalda G Martins
  • Luísa I Silva
  • José M Nunes
چکیده

BACKGROUND Carinal hooks increases difficulty at endotracheal intubation. Amputation of the carinal hook during passage and malpositioning of the tube to the hook are some of the potential problems related with left-sided Carlens double lumen tube (DLT). This article reports an amputation of the hook during a difficult selective intubation and aimed at calling the attention to complications associated with DLTs and the importance of fiberoptic bronchoscopy. CASE PRESENTATION A 68 year-old woman was scheduled for right-sided thoracotomy in whom blind DLT insertion was performed. Narrowed trachea causes difficulty in rotating the DLT 90° counter-clockwise. After carinal hook was noticed upon visual inspection of the DLT, fiberoptic bronchoscopy was used to remove the missing part (with the use of forceps) from the right mainstem bronchus. CONCLUSION Insertion of DLTs with carinal hook is associated with technical problems and potentially life-threatening hazards have discouraged their use. Fiberoptic evaluation and repositioning solves most of the problems. Although amputation of the carinal hook has not been previously reported, clinicians should be alert. This case report emphasizes the utility of the fiberoptic bronchoscopy in the operating theatre for placement, positioning and inspection of the carinal hook DLT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring incisor-carina distance by fiberoptic bronchoscopy to guide the placement of a left-sided double-lumen endobronchial tube

The aim of this randomized observational study was to evaluate the effect of measuring the incisor-carina distance by fiberoptic bronchoscopy in guiding the placement of a left-sided double-lumen endobronchial tube. Fifty patients (American Society of Anesthesiologists class I-II) undergoing elective thoracic procedures requiring single-lung ventilation using a left-sided double-lumen endobronc...

متن کامل

Left double-lumen tube with or without a carinal hook: A randomised controlled trial.

BACKGROUND Left double-lumen tracheal tubes (DLTs), with or without a hook to engage the carina, remain the standard device for lung isolation during anaesthesia. OBJECTIVE The purpose of the study was to compare these DLTs with and without a hook. DESIGN A randomised, controlled, single-blinded study. SETTING University hospital. PARTICIPANTS One hundred and eighty-four patients underg...

متن کامل

Left mainstem bronchial rupture during one-lung ventilation with Robertshaw double lumen endobronchial tube -A case report-

Lung separation using a double-lumen endobronchial tube is necessary for video assisted thoracoscopy (VATs). Bronchial rupture after intubation with a double-lumen endobronchial tube has been rarely reported. We report a case of a 70-year-old man who had solitary pulmonary nodule in his right upper lobe. He was intubated with a left-sided Robertshaw double-lumen endobronchial tube. He underwent...

متن کامل

Clinical review: Independent lung ventilation in critical care

Independent lung ventilation (ILV) can be classified into anatomical and physiological lung separation. It requires either endobronchial blockade or double-lumen endotracheal tube intubation. Endobronchial blockade or selective double-lumen tube ventilation may necessitate temporary one lung ventilation. Anatomical lung separation isolates a diseased lung from contaminating the non-diseased lun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011