Assessment of aortic insufficiency by transcutaneous Doppler ultrasound.
نویسنده
چکیده
Using a 2.2 MHZ directional Doppler ultrasound unit, the instantaneous peak aortic velocity pattern was recorded transcutaneously in 15 normal persons and 15 patients with aortic insufficiency. The transducer was positioned in the suprasternal notch and aimed posteriorly to cross the descending aortic arch at an angle approximately parallel to blood flow. The electrocardiogram, phonocardiogram, and carotid pulse tracings were recorded simultaneously. In patients with aortic insufficiency there was significant diastolic flow that was not present in normal persons. The planimetered area under the systolic and diastolic velocity tracings represents the distance forward and backward that the stroke volume moves. The ratio was used to approximate the percent regurgitation, which ranged from 9% to 68%. From left ventricular angiograms in the patients with aortic regurgitation single plane ventricular volume measurements were used to calculate ventricular output and when compared with the Fick cardiac output gave an estimate of true percent regurgitation. A strong correlation was obtained with the Doppler estimate (r=0.91), confirming that this simple ultrasound technique can accurately assess the degree of aortic insufficiency.
منابع مشابه
Hypertrophic obstructive cardiomyopathy. Assessment by echocardiographic and Doppler ultrasound techniques.
Hypertrophic obstructive cardiomyopathy is a disease of the myocardium that can be assessed echocardiographic and transcutaneous Doppler ultrasound techniques. Four patients are presented with various patterns of the disease, and the frequently familial incidence is illustrated. The importance of ultrasonic evidence for asymmetric septal hypertrophy in all stages is emphasized and evidence of r...
متن کاملNoninvasive assessment of mitral insufficiency by transcutaneous Doppler ultrasound.
Instantaneous aortic arch blood velocity was recorded transcutaneously from the suprasternal notch, using a 2.2 MHz Doppler ultrasound unit, in 18 normals and 16 patients undergoing cardiac catheterization who had murmurs of mitral regurgitation. In normals aortic blood velocity rose rapidly in early systole to a midsystolic peak then fell to zero velocity. These roughly parabolic patterns had ...
متن کاملInfluence of different positions on hemodynamics derived from noninvasive transcutaneous Doppler ultrasound
A proper alignment of the ultrasound beam to the aortic or pulmonary outflow tracts is essential to acquire accurate signals. This study aimed to investigate the influence of different positions on the acquisition of Doppler signals using a noninvasive transcutaneous Doppler ultrasound. This was a prospective observational crossover study. Two operators performed hemodynamics measurements on ea...
متن کاملAssessment of energy loss in aortic stenosis using Bayesian multipoint phase-contrast MRI
Background Aortic stenosis is the most prevalent valvular heart disease. The current gold standard for determination of the disease severity is Doppler echocardiography, but the decision for valve replacement is mostly based on the patient experiencing symptoms [1]. Doppler echocardiography measures the velocity across the valve, which is only indirectly linked to the energy loss associated wit...
متن کاملClinical evaluation versus Doppler echocardiography in the quantitative assessment of valvular heart disease.
We tested the hypotheses that Doppler echocardiography has a higher accuracy than clinical evaluation in the detection of significant aortic and mitral valvular heart disease and that Doppler echocardiography is highly accurate as compared with cardiac catheterization for the assessment of valvular disease severity. Thus, cardiac catheterization for the assessment of valve lesion severity may b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 52 5 شماره
صفحات -
تاریخ انتشار 1975