Standard-dose vs. low-dose CT protocols in the evaluation of localized lung lesions: Capability for lesion characterization—iLEAD study☆

نویسندگان

  • Takeshi Kubo
  • Yoshiharu Ohno
  • Daisuke Takenaka
  • Mizuki Nishino
  • Shiva Gautam
  • Kazuro Sugimura
  • Hans Ulrich Kauczor
  • Hiroto Hatabu
چکیده

OBJECTIVE To determine the lesion characterization capability by low dose CT for localized lung lesions in comparison with standard dose CT. SUBJECTS AND METHODS Approval for this study was granted by our Institutional Review Board. Fifty-two consecutive patients (36 males and 16 females, median age of 71 years.) who had CT examinations for evaluation of lung lesions comprise the study population. Two chest CT scans were performed with current time product of 50 and 150 mAs at 120 kVp, with the same scan length with a 16 detector-row CT scanner. Three readers evaluated 52 target lesions and assigned an overall impression score to each target lesion, using a 5 point scale from 1 (definitely benign) to 5 (definitely malignant). Six features of the lesions including lesion type, margin characteristics, calcification, lobulation, speculation, and pleural indentation were also reported with 5-point scales. The weighted kappa analyses and receiver operating characteristic analysis were used for analysis. RESULTS The mean kappa value between low-and standard-dose CT was 0.82 for overall impression of the lesions, showing almost perfect agreement. Area under the curve of low-dose CT (Az = 0.74) had no significant difference from that of standard-dose CT (Az = 0.74) (p = 0.61). The kappa values for six lesion features ranged from 0.45 to 0.83, showing moderate to almost perfect agreement. CONCLUSION Lesion characterization capability by low-dose CT images was comparable to that by standard-dose CT images and therefore sufficient for evaluation of localized lung lesions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing radiation doses in female breast and lung during CT examinations of thorax: A new technique in two scanners

Background: Chest CT is a commonly used examination for the diagnosis of lung diseases, but a breast within the scanned field is nearly never the organ of interest.Objective: The purpose of this study is to compare the female breast and lung doses using split and standard protocols in chest CT scanning.Materials and Methods: The sliced chest and breast female phantoms were used. CT exams were p...

متن کامل

Clinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment

Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...

متن کامل

Optimization of Head CT Protocol to Reduce the Absorbed Dose in Eye Lenses and Thyroid: A Phantom Study

Introduction: Utilization of computed tomography (CT) scans is increasing annually. This study aimed to reduce the absorbed dose of sensitive organs in the head (eye lenses and thyroid) and to assess changes in resultant images quality in head scans when the radiation dose is decreased. Material and Methods: An anthropomorphic phantom was examined with head protocols in both helical and sectio...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

Evaluation of Effect of Different Computed Tomography Scanning Protocols on Hounsfield Unit and Its Impact on Dose Calculation by Treatment Planning System

Introduction: In radiotherapy treatment planning system (TPS), basic input is the data from computed tomography (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016