Direct Parametric Reconstruction for Dynamic [18F]FDG PET/CT Imaging in the Body
نویسندگان
چکیده
Abdominal and thoracic [F]FDG PET/CT imaging is routinely used in clinical practice and drug development but parametric imaging based on full kinetic analysis is rarely used due to noise induced bias and variance in kinetic parameters and analysis is usually restricted to semi-quantitative indices. Direct parametric estimation using 4D image reconstruction can potentially provide parametric maps of reduced bias and variance but little or no evaluation has been done in the body. Previous studies have demonstrated that body [F]FDG PET/CT imaging can benefit from these methods but analysis was restricted to macroparameters of interest. In work, we implement and apply a recently proposed direct 4-D algorithm using a 2 tissue compartment model on simulated and real oncology [F]FDG PET/CT data to directly estimate microparameters of interest and assess potential improvements over the traditional post-reconstruction kinetic analysis. Results on the simulated data suggest clear reduction in bias for K1, k2 and blood volume and less for k3. Similarly, variance reduction was observed for K1, k2, k3 and Ki and less for blood volume. Evaluation on patient data demonstrated similar improvements using the direct 4-D method in agreement with simulations.
منابع مشابه
18F-FDG PET/CT in Neurolymphomatosis: Report of 3 Cases
Neurolymphomatosis is a rare manifestation of non-Hodgkin lymphoma characterized by infiltration of peripheral nerves, nerve roots, plexus and cranial nerves by malignant lymphocytes. This report presents positron emission tomography/computed tomography (PET/CT)imaging with 2-deoxy-2-18F-fluoro-D-glucose (18F-FDG) in 3 cases of non-Hodgkin lymphoma with nerve infiltration, including one newly d...
متن کاملF-18 FDG PET/CT imaging of primary hepatic neuroendocrine tumor
Primary hepatic neuroendocrine tumors (PHNETs) are extremely rare neoplasms. Herein, we report a case of a 70-year-old man with a hepatic mass. The non-contrast computed tomography (CT) image showed a low-density mass, and dynamic CT images indicated the enhancement of the mass in the arterial phase and early washout in the late phase. F18- fluorodeoxyglucose (18F-FDG) positron emission tomogra...
متن کاملFactors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging
Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...
متن کاملGeneralized lymph node activation after Influenza vaccination on 18F FDG-PET/CT imaging, an important pitfall in PET interpretation
We report on a 59-year-old female patient with an infected vascular graft investigated with 18F FDG-PET/CT. The first of two studies showed FDG activity in the left deltoid and ipsilateral axillary lymph nodes explained by influenza vaccination the day prior. The second 18F FDG-PET/CT showed multiple FDG-avid lymph nodes on both sides of the diaphragm without tracer accumulation at the vaccinat...
متن کاملA Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.
Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012