Kallow et al: MALDI-TOF MS for Microbial Identification
نویسندگان
چکیده
Immediately after the first MALDI-TOF instrument became available, microbiologists have been investigating its potential as a platform for high throughput identification of microorganisms. A remarkable finding very early in these investigations was that despite the dynamic nature of the bacterial cell, components of the mass spectral profile were sufficiently stable and remained unchanged in spite of changes in environmental parameters. Further, mass spectral patterns have been found to be taxon specific, consequently, numerous methods were reported that purported to provide an alternative to current identification systems. The SARAMIS system described herein sequentially extracts core stable mass ions from analyses of multiple individual strains of a particular species to yield a ‘SuperSpectrum’, a list of biomarkers that are weighted according to their specificity from family to (sub)species levels. This approach has been used successfully to identify microorganisms from diverse phylogenetic lines of bacteria and fungi with considerable success. The protocol described has evolved of over years of experimental work to yield a robust system that can be readily applied for microbiological identification in a clinical diagnostic laboratory. Identification of Microorganisms in Clinical Routine A crucial step in the epidemiology and the successful therapy of any infectious disease is the identification of the causative microbe. For more than a century, clinical microbiology has relied on the isolation of the suspected pathogen from various samples such as stools, throat swabs, blood, or urine on selective growth media and an identification procedure that is based on the metabolic capacities of the isolate. An array of carbohydrate fermentation and enzymatic reactions are tested that generally involve a colour change of an indicator when a particular substrate is catabolised. The profile of positive and negative reactions is assumed to be characteristic for a bacterial taxon and is consequently used for identification. Modern microbial identification systems are miniaturized, combining some tens of reactions into a single strip or card to allow for high throughput analysis. The major shortcomings of these systems are the need to incubate isolates for several hours to obtain pure cultures, and a required pre-selection of tests. Although this is still the most commonly used method in clinical diagnostic laboratories, microbiologists have been seeking alternative methods for the identification of pathogens for decades. A new era has dawned with the arrival of molecular methods such as the polymerase chain reaction (PCR) and nucleotide sequence analysis. In diagnostic and systematic microbiology today, analysis of genomic sequences is rapidly displacing biochemical tests for the provision of new characters for the circumscription of taxa. For example, a prerequisite for the description of a new species is the inclusion of the sequence of the 16S rRNA gene which now plays a pivotal role in microbial phylogeny. However, despite the widespread use of PCR and sequencing in all fields of microbiology, the technology is still lagging behind in clinical microbiology and is Shah, Gharbia, Encheva (Eds.) Mass spectrometry for microbial proteomics largely restricted to research applications. On the other hand, the high sensitivity and specificity of molecular methods make them indispensable in modern microbiological laboratories, as for example in the detection of methicillin resistant Staphylococcus aureus (MRSA) by real-time PCR assays, or the identification of atypical or very rare pathogens. Mass Spectrometry and Microbiology The application of chemical analyses (referred to as chemotaxonomy) for the identification and classification of microorganisms has been explored extensively prior to molecular analysis. These were based on the characterisation of polar (eg. phospholipids) and non polar lipids such as respiratory quinones (eg. ubiquinones and menaquinones) and long-chained cellular fatty acids . The structure of these lipids were challenging and ushered in a period of intense mass spectral analysis to characterise the vast array of lipids present in the microbial kingdom. While these methods provided characters at the genus and species levels, pyrrolysis mass spectrometry was introduced as a means of typing bacterial isolates . Such approaches were motivated by the need for a rapid method to identify pathogens in only a fraction of the time required for biochemical tests. However, because of the limitations of the technology at that time, mass spectral approaches were confined to the detection of organic molecules in a mass range up to 1,500 Da . Detection of larger molecules was hitherto only possible with techniques such as plasma desorption mass spectrometry . But this was about to change dramatically within a few years with the invention of Matrix-Assisted Laser Desorption/Ionisation Time-of-Flight Mass Spectrometry (MALDI-TOF MS) and its success in many fields of life sciences has been phenomenal. The laser desorption and mass spectral analysis of large biomolecules was developed simultaneously by two research groups in Japan and Germany. While the group of Tanaka could successfully detect proteins up to m/z 100,000 Da by direct laser ionization , Karas and Hillenkamp 6 relied on a light absorbing matrix, and achieved similar results by this method. A matrix effect on the desorption rate was observed earlier for smaller molecules 7 and further studies quickly directed the search for matrix candidates to a few small organic molecules that are still the primarily used ones in MALDI-TOF MS applications today, viz. cinnamic acid derivatives 8 and 2,5dihydro benzoic acid . Accuracy and resolution could be significantly improved by the introduction of delayed ion extraction , which compensates for the variability in initial ion velocity . The sensitivity of MALDI-TOF MS for the detection of large proteins was rapidly increased to the femtomolar range 12 and further, aided by sophisticated handling procedures to the zeptomolar range . Within less then a decade, MALDI-TOF MS developed into a widely applied methodology in diverse fields of life sciences , promoted by a number of major advantages it had compared to other mass spectral technologies. These included the possibility to detect unfragmented large molecules, the speed with which a full scan over a wide mass range can be achieved, and the simplicity of sample preparation. For the analysis of whole cells and crude extracts, an outstanding advantage of MALDI compared to other ionization techniques such as electrospray ionization (ESI) or fast atom bombardment (FAB), is the fact that in MALDITOF MS predominantly singly charged ions are detected 15 which simplified the interpretation and treatment of mass spectral data considerably . Mass Spectral ‘Fingerprints’ of Whole Cells The possibility of introducing whole cells into a mass spectrometer and detecting biomolecules in a mass range extending to several kilodaltons was immediately recognised by microbiologists. Shortly after the first MALDI-TOF MS was commercially available (by Vestec and Kratos) the first reports on intact cell mass spectrometry of bacteria were published, some of which highlighted its potential for microbial diagnostics . Essentially these studies showed that mass spectra of whole cells of bacterial strains revealed patterns of mass signals that were reproducible and specific for strains or species. Because cells could be analysed after minimal processing and preparation, required only minute biomass, either as a cell suspension or cells placed directly on a target plate, the implications for diagnostic microbiology were immediately evident and numerous studies ensued. The mass ranges that were selected in early studies varied from m/z 500-2200 18 to m/z 200020000 . In the lower mass range, constituents of the cell wall are detected, and also, but to a lesser degree protein components . The lower mass range was also used for the typing of potentially toxic cyanobacteria 24 and proved to be suitable for the metabolic typing of sub-specific taxonomic units in natural populations . The possibility that mass fingerprints could be used to classify and eventually identify Kallow et al: MALDI-TOF MS for Microbial Identification 3 unknown microbial isolates was pursued in the following years by a number of groups. Most studies focused on the detection of proteins in mass ranges spanning from above m/z 2000 to below m/z 25,000. The identity of proteins detected at this time was not very clear because only a few genomic sequences of microorganisms were available. It was generally assumed that the proteins desorbed from whole cells, that were not subjected to typical mechanical or chemical lysis, were attached to the cell surface . However, studies on membrane-associated proteins of E. coli K12, revealed that the molecular mass of most of these proteins exceeded 20 kDa 26 and were likely to be intracellular proteins. Comparative MALDI-TOF mass spectral studies of isolated ribosomal subunits with those of whole cell mass spectra of E. coli K12 revealed that they shared a large number of mass signals that are commensurate with ribosomal proteins 27 (Figure 1). This large number of ionised ribosomal proteins is in accord with the high level of these proteins (ca. 30% of total proteins) of a cell in its exponential growth phase. Furthermore, studies on isolated ribosomes also revealed that many proteins were modified posttranslationally, and that the observed mass signals were in agreement with the general rules for methionine cleavage . Such studies emphasised that direct ‘translation’ of genomic data in mass patterns is not straightforward. Further microbial taxa have been studied in detail to reveal the identity of proteins detected by whole cell mass spectrometry. A high level of observed peaks in mass spectra could be assigned to ribosomal proteins in Helicobacter pylori , Saccharomyces cerevisiae (together with mitochondrion related proteins) , Campylobacter jejuni , Lactobacillus plantarum , and Pseudomonas putida . With the growing number of completed genomes in databases, the assignment of mass signals to proteins will be extended to further species. In Figure 2, a mass spectrum of a clinical isolate of Streptococcus pneumoniae is shown with the mass signals matching to theoretical masses of ribosomal proteins obtained from the SwissProt database. Other proteins identified in whole cell mass spectra include for example, DNA-binding proteins 31 and a protein in E. coli that correlates with the possession of an Fplasmid (m/z 9743) . The latter example also underlines the limits of in silico studies, since no candidate among some thirty proteins encoded on the F-plasmid had a sequence matching the observed mass signal when considering only modifications such as methionine cleavage or methylation. The in vivo protein could be further modified for example by cyclisation or formation of di-sulfide bridges, or cleaved from a larger premature protein. The detection of ribosomal and other small structural proteins (i.e., proteins without a direct metabolic function) in whole cell MALDITOF mass spectra of various microbial taxa is very promising for the development of identification systems for clinical applications. To this end, two major objectives need to be addressed. Firstly, the reproducibility of mass fingerprints acquired under various culture conditions, on different instruments, or from multiple strains of a single species and, secondly, the discriminating power of mass fingerprints among recognized species. Reproducibility of Mass Spectral Fingerprints A principle problem for the development of a standard protocol using mass spectrometry is the fact that even replicate analyses of a single clone do not result in identical mass fingerprints. This applies to the individual peak’s height as well as to the presence and absence of peaks, primarily of those with low intensities. The reproducibility of mass spectral fingerprints therefore has been the subject of a number of studies assessing biological, physical, and chemical effects on whole cell mass spectra. Wang et al. 35 demonstrated that variations in the sample preparation procedures and in the experimental conditions resulted in a significant change in the observed spectra, especially in relative peak intensities. Thus, a number of peaks were observed in the spectra from the same bacterial sample obtained under different conditions, especially when acidic extraction was employed. Similar observations were made by Williams et al. 36 who also reported that acidification of the matrix solution with 1-2.5 % TFA yielded the best results in terms of peak number and reproducibility with different matrices. The shape of recorded peaks is itself dependent on a number of factors such as sample concentration and laser intensity, and consequently these factors need to be optimised for a given instrument . Since peak recognition partly depends on the software settings rather than on the hardware components, a sample preparation procedure that yields reproducible results on one MS is likely to be suitable for others. This was assessed in an inter-laboratory study where a single sample was analyzed in three laboratories on different mass spectrometers . Again, a number of mass sigShah, Gharbia, Encheva (Eds.) Mass spectrometry for microbial proteomics nals were invariably recorded in all fingerprint spectra, while others were recorded with differing frequency in different laboratories. Thus, to a certain degree differences in whole cell mass spectra of a single bacterial sample can be attributed to physical and chemical factors. This is important to note since spectrum-to-spectrum variability could be mistakingly taken to indicate biological differences. Biological variability is expected in whole cell mass spectral fingerprints due to the dynamic regulation of protein expression in response to growth conditions and culture age. Thus, for E. coli it was shown that mass spectral profiles changed with cultivation time . Assuming that the mass ions of the ribosomal proteins are recorded in mass spectral fingerprints of many species, it is expected that the signal intensity of these proteins will be highest in the exponential growth phase. Figure 3 shows the mass spectra of whole cells of Proteus mirabilis recorded after cultivation times varying between 16 to 120 hours. Although the quality of the mass fingerprint declines considerably after 48 hours (in terms of peak number and resolution) the major mass signals were still recorded and allowed automated identification (see below). However, our own observations have shown that the effect of culture conditions on mass spectral fingerprints is less pronounced than would be expected considering the complex system of protein expression in living cells. This was confirmed by Valentine et al. 40 who examined the mass spectra of several species using different culture media and Wunschel et.al who additionally analysed cells grown at different temperatures, pH, and growth rates . Species and Strain Discrimination by Mass Spectrometry Early studies that explored the use of mass spectral fingerprints tested the discriminating power on rather distantly related taxa, however, as confidence grew in the potential of the technique, more closely related taxa were studied (Table 1). Bacillus spores and cells have been studied intensively because of their potential use as bioterrorism agents and the need for a fast, safe and reproducible method to identify them in suspicious samples. It proved that with MALDI-TOF MS (and other mass spectral techniques) cells and spores of one of the most dangerous species, B. anthracis and the generally inseparable species, B. cereus, could be differentiated . Reliable biomarkers were reported as ‘small acid soluble proteins’ (SASP) that were characteristic of a number of strains 45 and had the potential for identification of cells and spores . Lynn et al. 48 studied a number of Enterobacteriaceae of different genera and showed that a small number of mass signals were recorded for all strains, e.g., m/z 4364 (ribosomal protein L36), 5380 (ribosomal protein L34), and 6856 (YcaR). For particular genera, species, and strainsspecific mass signals could be identified that allowed the discrimination of E. coli, Klebsiella pneumoniae, Providencia rettgeri, and Salmonella typhimurium. Such studies illustrated that mass spectral fingerprints can potentially be used for the classification of bacterial strains. Further studies showed that environmental Escherichia coli isolates could be classified by MALDI-TOF MS according to their origin. Thus, avian E. coli isolates could be distinguished from those of bovine origin . In other studies, clinically relevant Streptococcus species were analysed by MALDI-TOF MS. Identification and differentiation of Streptococcus species is generally challenging by routine clinical methods while some groups of species sharing more than 99% nucleotide sequence similarity in the 16S rRNA gene. However, using MALDI-TOF MS mutans streptococci could be discriminated down to the subspecies level 50 permitting the reclassification of some strains. Similarly, Streptococcus pyogenes strains could be identified correctly and differentiated into invasive and non-invasive isolates . Streptococcus strains belonging to the viridans group were analysed by Friedrichs et al. 52 and shown that closely related species such as Str. mitis and Str. oralis could be reproducibly separated. Some twenty clinically relevant species and subspecies of Staphylococcus were studied by Carbonelle et al. 53 who reported that each species had a distinct mass spectral fingerprint that allowed its discrimination, allowing the high throughput identification of Staph. aureus. Discrimination between methicillin-resistant (MRSA) and methicillin-susceptible (MSSA) Staphylococcus aureus strains by MALDI-TOF MS was reported by Edwards-Jones et al. 55 and Du et al. . Both types of strains differed in mass signals around m/z 2500 and their assignment was in accordance with the results of a mecAspecific PCR assay. A few exceptions, however, were observed and the discrimination of MRSA and MSSA by MALDI-TOF MS could not be confirmed by the analysis of further strains (AnagnosTec, unpublished data; ). Nonetheless, considering the high costs of MRSA identification by real-time PCR assays, an alternative Kallow et al: MALDI-TOF MS for Microbial Identification 5 methodology would be advantageous. Since MRSA are not a monophyletic unit but have arisen from different MSSA lineages independently 58 new approaches will require a different strategy. Direct detection from whole cells of gene products of the staphylococcal chromosomal cassette (SCCmec) responsible for the βlactam resistance is, however, unlikely to be feasible. The penicillin binding protein 2a, for example, has a mass of 78 kDa, far beyond the mass range generally used for mass fingerprinting. Methods involving surface enhanced laser desorption/ionisation (SELDI TOF MS) shows promise . This technique has also been used to delineate subspecies of Francisella tularensis, the causative organism of tularaemia . A number of Mycobacterium species were found to be distinguishable by mass spectrometry, and strains could even be discriminated when mass signal intensity was accounted for in addition to simple presence/absence data . As agents of bioterrorism usually do not emerge in laboratory settings, a procedure is required to make any potentially hazardous substance innocuous immediately, without disabling its biomarkers for subsequent identification. A number of Bacillus (spores and cells) and Yersinia species were studied for the applicability of a thorough inactivation protocol prior to mass spectral characterization . Cells and spores were treated with 80% trifluoroacetic acid resulting in complete inactivation that did not significantly deteriorate the quality of mass spectral fingerprints, which could still be used for identification. Compared to bacteria, far less attention has been given to the mass spectral analysis of fungi. However, the few studies undertaken so far indicate that pathogenic fungi can also be identified by whole cell MALDI-TOF MS. Closely related wood decay fungi could be discriminated and identified . Clinical isolates of dematophytes could be automatically identified by matching the isolates’ spectra to a spectral database . An infection with Fusarium proliferatum was confirmed by mass spectral typing and comparison to reference strains . A major obstacle in the mass spectral identification of fungi is the variability in a strain’s mass fingerprint due to cell differentiation and spore formation. Among the protists, some notorious pathogens are relevant for public health surveillance such as Giardia lamblia or Cryptosporidia. Both taxa have been analysed by MALDI-TOF MS and the results suggest that mass spectral fingerprints can also be applied for their correct identification . Proof of principle has been demonstrated for several species (see Table 1) but the shortcomings of some studies prevent their direct transfer to a diagnostic laboratory. Firstly, in many studies only a limited number of strains were tested, which is unlikely to fully represent the intra-specific diversity of a given taxon, and secondly, because these identification principles have only rarely been tested for unknown samples For mass fingerprints to be used for the routine identification of unknown samples, methods have to be developed that treat the mass spectral information in a reproducible and standardized manner, which can then be compared with reference mass spectra of well characterized strains. Pattern Matching Approaches for automated Identification In general, the comparison of mass spectral fingerprints is done by mathematical approaches based on various algorithms for cluster analyses, or multivariate approaches such as principal component analysis. The key issue for a successful method is not the particular algorithm that is applied to the processed data since different algorithms may lead to very similar results . However, the processing of the raw data and the identification of mass signals is of paramount impotance. Different approaches have been proposed for pattern matching procedures. Arnold and Reilly 68 applied a cross-correlation analysis to mass spectra of 25 E. coli strains by dividing the full spectrum in a varying number of intervals. By this procedure, individual strains could be discriminated even when the corresponding mass spectra appeared very similar. Demirev et al. 69 proposed a combination of mass spectrometry and protein database search to assign signals in the mass spectrum of an unknown bacterial sample to a protein sequence translated from internetaccessible genomic sequences. Jarman et al. 70 developed an algorithm for the extraction of fingerprints from mass spectra (m/z 1,000-10,000) of bacteria considering the variability in intensity, frequency, and accuracy of mass signals in replicate analyses of an individual strain. By doing so, a fingerprint was calculated that accounts for differences in replicate mass spectra caused by physiological regulation, analytical error and detection limit. The extracted fingerprint data was applied to the comparison of blind samples with library reference fingerprints of five species by calculating similarities between an unknown and a reference fingerprint based on the absence Shah, Gharbia, Encheva (Eds.) Mass spectrometry for microbial proteomics and presence of individual biomarkers . For the blind samples, the same strains and mixtures thereof with Shewanella alga cells were used, and fingerprints calculated from repeated analyses. For all species except Bacillus cereus, a correct identification was achieved when these were part of the mixture, and for all strains correct negative results were returned in the case of their absence. Bright et al. 72 applied a pattern recognition algorithm to mass spectra in a range of m/z 500-10,000. The software tool MUSE translated each quality-controlled mass spectrum into a single point vector in an n-dimensional space. The spectra of replicate samples of a strain had a location in an n-dimensional space close to, but not identical to each other. As a reference library the mass spectral data of 35 strains from 20 species were included. When the same strains were analysed as blind samples, the correct match was achieved for more than 95% on the species level. A hierarchical clustering algorithm was applied by Hsieh et al. 73 in combination with analysis of variance (ANOVA) to extract biomarkers from multiple isolates belonging to six human pathogens. The set of specific markers was then reduced to 2-4, which was sufficient to identify isolates of the same species correctly. Mass Spectral Identification of Microorganism – Requirements for Routine Diagnostics The proof of principle of mass spectral identification of microorganisms has been shown for various taxa (see Table 1). This is an essential prerequisite for diagnostics in clinical microbiology but for daily routine use there are further demands. Thus, mass spectral identification needs to be simple and fast in handling robust to account for variations and variability in culture conditions reproducible to allow identifications at different locations applicable to the majority of clinically relevant microorganisms economic to allow identifications at competitive costs The measuring process itself, as described in most publications, is straightforward. Several extraction solvents and matrix compounds have been tested for their effect on resulting mass fingerprints . Despite various suggestions for extraction procedures, cells of most taxa can generally be applied directly to sample targets, either from solid media or from suspensions. One particular exception, yeasts, have been shown to result in considerably improved mass fingerprints after an additional extraction step with formic acid , but for most bacteria, extraction performed on the sample spot by adding matrix solution can be considered as sufficient. Extraction procedures involving more steps may lead to increased reproducibility, but at the expense of a significant increase in handling time. Once raw mass spectra have been obtained, mass signals need to be processed by peak detection algorithms to extract the relevant information for further analysis. Although this is performed by all software packages supplied with a mass spectrometer, differences in peak recognition algorithms can have a considerable effect on the processing and need to be adjusted with care . Raw data could be used for spectral comparison directly, e.g., by the BioNumerics software package as it has been applied to mass spectra of Burkholderia cepacia complex species by Vanlaere et al. . A major disadvantage of this approach is the extended computing time for large datasets. For practical reasons therefore, the extraction of peak data from raw mass spectra substantially facilitates the downstream data handling, and can be generally performed with the MS software with appropriate settings for baseline correction, noise filtering, etc. Finally, the identifying step involves the comparison of the mass spectral fingerprint of an unknown sample with the mass spectral fingerprints of well characterized strains. The principles applied to the identification of microorganisms based on mass spectral fingerprints are essentially the same as for similar problems where a pattern recognition is required, for example, restriction fragment length polymorphism analysis. A major obstacle in this process is the fact that every mass signal in a spectrum has an analytical error. This is in contrast to the comparison of (nucleotide) sequence data where only discrete values are compared. In MALDI-TOF MS several factors contribute to the analytical error, e.g., small variability of acceleration voltage, shape of matrix crystals, and peak recognition by the processing software. For most linear MALDITOF mass spectrometers an error of some 500 ppm is considered as acceptable, i.e., a deviation of 5 Da for m/z 10,000 . A higher precision can be achieved by internal standards but for ICMS this is not applicable because the calibrants potentially interfere with biomarkers. In consequence, a particular biomarker is detected with a variability in m/z values that has to be taken into Kallow et al: MALDI-TOF MS for Microbial Identification 7 consideration when pattern matching algorithms are applied. The most important part of a system for automated mass spectral identification of microorganisms is a validated reference database . The reference database should contain not only the mass spectral data of pathogens but also of related, non-pathogenic species that are frequently found in a clinical environment to avoid the danger of false positive identifications that could lead to a superfluous and potentially stressful therapy. From these considerations, it is evident that a database needs to contain reference spectra of hundreds of microbial species. Such a database was established by AnagnosTec in 1998 and is constantly amended for rare and newly emerging pathogens, microbes relevant in veterinary medicine, and environmental species. In the next section the principle and workflow for automated mass spectral identification of clinical microorganisms using SARAMIS (Spectral archiving and microbial identification system) is briefly explained and examples of the application in routine laboratories are given. Automated Mass Spectral Analysis of Microorganisms in Clinical Routine Diagnostics The identification system SARAMIS consists of a database containing reference spectra, and software that allows the comparison of the mass fingerprint of an unknown sample to the reference spectra and was developed by AnagnosTec. The same principle is applied in the BioTyper software package developed by Bruker Daltronics . As reference spectra, SARAMIS uses so-called “SuperSpectra” that have been calculated from replicate mass spectra of multiple isolates of a single species or sub-species. To generate SuperSpectra, high quality mass spectra of a species of interest are collected from multiple strains grown under varying conditions and in different laboratories. Raw mass spectra are then processed to yield peak lists, that are subjected to cluster analysis by applying a single link agglomerative clustering algorithm that allows a pre-set analytical error, generally 500 ppm. Each cluster represents a mass fingerprint type of a species as shown in Figure 4. When numerous strains of a single species have been analysed, cluster analysis may reveal sub-specific units and in that case, multiple SuperSpectra can be calculated. In the next step, a consensus spectrum is calculated containing only these mass signals that have been recorded in a frequency of 50-100% to exclude unspecific signals. This threshold frequency needs to be taxon-specific with a dataset at hand that allows estimation of the intraspecific variability. Consensus spectra inevitably contain peaks that are specific for higher taxonomic units such as genera or families which can give mass spectral fingerprints of members of respective taxa a high background similarity (see, for example, Enterobacteriaceae , Figure.4). For species identification respective mass signals cannot be reclaimed and are given a low weighting. For the calculation of SARAMIS SuperSpectra such nonspecific mass signals are identified by comparing each m/z-value to m/z-values in the entire database of reference spectra (> 100,000; 2009). Before SuperSpectra are released for automated identification, each mass signal contained therein is weighted according to its specificity for the taxon it represents, e.g., a mass signal that has been recorded exclusively with high frequency in one species receives a high value while one that has been recorded in multiple species of the same family receives a lower value. When a mass spectral fingerprint is matched to the SuperSpectra in the database, weighting values for each matching mass signal are summed up and as a result those SuperSpectra for which the highest specific concordance was established are listed. The sum of the mass signal specific match values can then be translated into a confidence value for identification. The performance of SARAMIS was evaluated in several clinical diagnostic laboratories , and the results of one study presented here. In 2007, routine identification of isolates from human urine samples was performed with two systems in parallel in the laboratory of Dr. Stein (Mönchengladbach, Germany). Samples were analysed by the VITEK 2 system already established in the laboratory as well as by MALDI-TOF MS/SARAMIS that was set up in the laboratory in 2007. A total of 569 bacterial isolates were analysed by both methods representing the commonly encountered, clinically relevant taxa, including diverse species of Enterobacteriaceae, gram-positive cocci, and nonfermentative species. Both methods yielded consistent results for 96.6% of all isolates, including 6.3% for which the SARAMIS identification was correct but only with a confidence level of 80-90% (Table 2). The best hit rates were achieved for Enterobacteriaceae and Nonfermenters (98 and 100%, respectively) while for staphylococci and Entero/streptococci only 92.4 and 82.8% correct identifications were attained, respectively. For these two groups, the highest number of unidentified isolates or isolates for which automatic data Shah, Gharbia, Encheva (Eds.) Mass spectrometry for microbial proteomics acquisition did not yield a mass fingerprint were encountered. Thus, although the mass spectrum had passed the quality control, when a match to SuperSpectra accounts to < 70% confidence, SARAMIS issues a non identification result. The main reason for a negative result is generally gaps in the database, either encompassing rare species for which sufficient date have not yet been collected or subtypes of well-characterized species for which the mass fingerprint deviates considerably from typical mass fingerprints of that species. For example, in Streptococcus sp. the transition between species is frequently accompanied by new mass fingerprint types (own, unpublished data). For 1.1% of the isolates, no mass fingerprint could be generated by automated spectrum acquisition, but in the manual data acquisition mode for part of these samples a mass spectrum could be obtained. One of the most important outcomes of the evaluation was that not a single sample was mis-identified. These results clearly underline that a massspectrometry based identification system is now readily available as a diagnostic tool for the clinical laboratory and can be implemented after a short familiarisation phase for the routine identification of clinical samples. Nonetheless, it has to be emphasized that mass spectrometry based identification of microorganisms has its limits. This is partly due to the fact that bacterial identification is based indirectly on a genomospecies concept (ie. genes translated into proteins that were detected) while classical clinical microbiology is based on phenotypic characters derived from metabolic profiles . A typical example is the Shigella species that are recognized by taxonomists as polyphyletic lineages within the species Escherichia coli . The main phenotypic characteristics of Shigella sp. are that they are non-motile and cannot metabolise lactose; characteristics that also occur, however, in enteroinvasive E. coli strains 84 and which cannot be determined directly by intact cell mass spectrometry. On the other hand, species discrimination by mass fingerprinting can be straightforward for taxa that are poorly discriminated by biochemical methods , for example for species of the Burkholderia cepacia complex . Consequently, the prospects and capacities of MALDI-TOF MS based and biochemical microbial identification procedures are not completely congruent and the application of the former in routine diagnostics will require some training by the medical staff to interpret the data. However, traditional biochemical tests are now giving way to genomics approaches for species identification especially since the introduction of 16S rRNA gene sequencing. Throughout the entire microbial kingdom, many groups of biochemically similar species have been further resolved and clarified based on 16S rRNA sequences and the current edition of Bergey’s manual has adopted this approach for a ‘road map’ of the microbial kingdom. There is therefore a great opportunity to interphase a MALDI-TOF MS based method with 16S rRNA sequencing to provide a modern and reliable approach to microbial identification. The simplicity, speed, and reliability of massbased identification techniques are indisputable advantages, and it is expected that the methodology will be strengthened by the large number of studies in progress and in the future will become part of the work of routine diagnostics laboratories. Acknowledgements We whish to thank Dr. Lothar Kruska for making the data of the SARAMIS evaluation available.
منابع مشابه
Applying Magnetic Bead Separation / MALDI-TOF Mass Spectrometry to Human Tear Fluid Proteome Analysis
protein identification (Koo et al., 2005; Cheng et al., 2005; Mirr et al., 2005; Gruns et al., 2005; Tomosugi et al., 2005; Kijlstra et al., 1989; Zhou et al., 2006; Li et al., 2005; Fung et al., 2004; de Souza et al., 2006), but these protocols are sometimes hampered by the small amount of tear fluid and its low protein concentration. For high-throughput analysis, surface-enhanced laser desorp...
متن کاملMatrix-assisted laser desorption ionization-time of flight mass spectrometry: a fundamental shift in the routine practice of clinical microbiology.
Within the past decade, clinical microbiology laboratories experienced revolutionary changes in the way in which microorganisms are identified, moving away from slow, traditional microbial identification algorithms toward rapid molecular methods and mass spectrometry (MS). Historically, MS was clinically utilized as a high-complexity method adapted for protein-centered analysis of samples in ch...
متن کاملComparative analysis of PCR-electrospray ionization/mass spectrometry (MS) and MALDI-TOF/MS for the identification of bacteria and yeast from positive blood culture bottles.
BACKGROUND Emerging technologies for rapid identification of microbes demonstrate a shift from traditional biochemical and molecular testing algorithms toward methods using mass spectrometry (MS) for the semiquantitative analysis of microbial proteins and genetic elements. This study was performed to assess the diagnostic accuracy of 2 such technologies, PCR-electrospray ionization (ESI)/MS and...
متن کاملMALDI-TOF MS in Microbiology Schubert and Kostrzewa
Within less than a decade matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has become a gold standard for microbial identification in clinical microbiology laboratories. Besides identification of microorganisms the typing of single strains as well as the antibiotic and antimycotic resistance testing has come into focus in order to speed up the microbio...
متن کاملAssessment of Reproducibility of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Bacterial and Yeast Identification.
Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has revolutionized the identification of clinical bacterial and yeast isolates. However, data describing the reproducibility of MALDI-TOF MS for microbial identification are scarce. In this study, we show that MALDI-TOF MS-based microbial identification is highly reproducible and can tolerate numerous ...
متن کاملApplication of MALDI-TOF MS for requalification of a Candida clinical isolates culture collection
Microbial culture collections underpin biotechnology applications and are important resources for clinical microbiology by supplying reference strains and/or performing microbial identifications as a service. Proteomic profiles by MALDI-TOF MS have been used for Candida spp. identification in clinical laboratories and demonstrated to be a fast and reliable technique for the routine identificati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009