A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters.

نویسندگان

  • Stephen Shiver
  • Michael Blaivas
  • Matthew Lyon
چکیده

BACKGROUND Arterial cannulation for continuous blood-pressure measurement and frequent arterial-blood sampling commonly are required in critically ill patients. OBJECTIVES To compare ultrasound (US)-guided versus traditional palpation placement of arterial lines for time to placement, number of attempts, sites used, and complications. METHODS This was a prospective, randomized interventional study at a Level 1 academic urban emergency department with an annual census of 78,000 patients. Patients were randomized to either palpation or US-guided groups. Inclusion criteria were any adult patient who required an arterial line according to the treating attending. Patients who had previous attempts at an arterial line during the visit, or who could not be randomized because of time constraints, were excluded. Enrollment was on a convenience basis, during hours worked by researchers over a six-month period. Patients in either group who had three failed attempts were rescued with the other technique for patient comfort. Statistical analysis included Fisher's exact, Mann-Whitney, and Student's t-tests. RESULTS Sixty patients were enrolled, with 30 patients randomized to each group. Patients randomized to the US group had a shorter time required for arterial line placement (107 vs. 314 seconds; difference, 207 seconds; p = 0.0004), fewer placement attempts (1.2 vs. 2.2; difference, 1; p = 0.001), and fewer sites required for successful line placement (1.1 vs. 1.6; difference, 0.5; p = 0.001), as compared with the palpation group. CONCLUSIONS In this study, US guidance for arterial cannulation was successful more frequently and it took less time to establish the arterial line as compared with the palpation method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review of Ultrasound-Guided Radial Artery Catheter Placement.

Radial artery catheters are commonly placed for continuous blood pressure monitoring, frequent arterial blood gas analysis, or frequent blood sampling for diagnostic testing. Radial artery cannulation can be challenging and ultrasound guidance has emerged as a valuable adjunct for the placement of radial artery catheters. The advantages of ultrasound guidance include: real-time visualization of...

متن کامل

Comparison of Dwell-Times of Two Commonly Placed Peripheral Intravenous Catheters: Traditional vs. Ultrasound-Guided

Introduction: Because establishing venous access in patients can be difficult and time consuming, the use of ultrasound to guide the insertion of peripheral intravenous catheters has become more common. Anecdotal evidence indicates ultrasound-guided catheter insertion may result in decreased catheter survival in the vein (dwell-time), but there is little evidence to support this observation. Th...

متن کامل

Analysis of radial artery catheter placement by respiratory therapists using ultrasound guidance.

BACKGROUND The use of ultrasound (US) guidance for radial artery cannulation has been shown to improve first attempt success rate, reduce time to successful cannulation, and reduce complications. We sought to determine whether properly trained respiratory therapists (RTs) could utilize US guidance for the placement of radial artery catheters. Primary outcome measurements were successful cannula...

متن کامل

A RANDOMIZED PROSPECTIVE COMPARATIVE STUDY OF FOUR METHODS OF BICEPS TENDONITIS TREATMENT: ULTRASOUND, LOW LEVEL LASER+ ULTRASOUND, INTRA-SHEAT AND EXTRA-SHEAT CONTICOSTEROID GUIDED INJECTION

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Academic emergency medicine : official journal of the Society for Academic Emergency Medicine

دوره 13 12  شماره 

صفحات  -

تاریخ انتشار 2006