Measurements of radiation levels inside the ESRF storage ring

نویسنده

  • P. Berkvens
چکیده

Radiation damage observed on a number of cables in the storage ring has triggered a series of radiation measurements inside the storage ring to assess dose levels during injection and during stored beam conditions. Photon dose rates have been measured in different locations, using small ionization chambers. The results show a strong spatial variation of the measured dose rates and indicate that the radiation damage is essentially due to synchrotron radiation. The measured dose levels allow us to make estimations of the integrated dose in certain areas of the storage ring over the lifetime of the ESRF. The paper also describes a beam loss monitoring system, using 32 ionization chambers installed inside the storage ring, allowing the quantifying of beam losses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive lenses as a beam diagnostics tool for high-energy synchrotron radiation

Parabolic compound refractive lenses (CRLs) for hard X rays have been used to image the electron beam at undulator and bending-magnet beamlines at the ESRF. The measurements yield the shape and size of the synchrotron radiation source, and show that CRLs with paraboloid surface shape can be used as a beam diagnostics tool at highenergy electron storage rings. The optical resolution of the imagi...

متن کامل

The European Synchrotron Radiation Facility Hydrostatic Leveling System –twelve Years Experience with a Large Scale Hydrostatic Leveling System

This paper will discuss the European Synchrotron Radiation Facility (ESRF) Hydrostatic Leveling Systems (HLS) composed over 500 sensors. Note that in this discussion an HLS instrument will generally be referred to as a captor or sensor. This generic term refers to the capacitive sensor, the vessel and the temperature sensor ensemble. Refer to figure 1 for a schematic of the ESRF HLS instrument ...

متن کامل

Study of gamma exposure rate in Mysore and Chamaraj Nagar district, Karnataka, India

Background: Humans beings are continuously exposed to ionizing radiation from natural sources. The main contributors to natural radiation are high-energy cosmic radiation and radioactive nuclides that originates in the earth’s crust. Exposure to high levels of radiation can cause serious health effects. In this study an attempt has been made to monitor the levels of environmental back...

متن کامل

Vibration of Magnet-girder Assembly

To improve the stability of the magnet-girder assemblies in the ESRF storage ring, vibration investigations have been carried out for in situ magnet-girder assemblies and a prototype. Characterisation tests were performed : operating response measurements, static stiffness measurements, modal testing. A finite element modelling (FEM) is being carried out for the prototype assembly. First result...

متن کامل

Optical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring

The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003