Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions

نویسندگان

  • Munish Chauhan
  • Woo Chul Jeong
  • Hyung Joong Kim
  • Oh In Kwon
  • Eung Je Woo
چکیده

BACKGROUND Magnetic resonance electrical impedance tomography (MREIT) has been introduced as a non-invasive method for visualizing the internal conductivity and/or current density of an electrically conductive object by externally injected currents. The injected current through a pair of surface electrodes induces a magnetic flux density distribution inside the imaging object, which results in additional magnetic flux density. To measure the magnetic flux density signal in MREIT, the phase difference approach in an interleaved encoding scheme cancels out the systematic artifacts accumulated in phase signals and also reduces the random noise effect by doubling the measured magnetic flux density signal. For practical applications of in vivo MREIT, it is essential to reduce the scan duration maintaining spatial-resolution and sufficient contrast. In this paper, we optimize the magnetic flux density by using a fast gradient multi-echo MR pulse sequence. To recover the one component of magnetic flux density Bz, we use a coupled partial Fourier acquisitions in the interleaved sense. METHODS To prove the proposed algorithm, we performed numerical simulations using a two-dimensional finite-element model. For a real experiment, we designed a phantom filled with a calibrated saline solution and located a rubber balloon inside the phantom. The rubber balloon was inflated by injecting the same saline solution during the MREIT imaging. We used the multi-echo fast low angle shot (FLASH) MR pulse sequence for MRI scan, which allows the reduction of measuring time without a substantial loss in image quality. RESULTS Under the assumption of a priori phase artifact map from a reference scan, we rigorously investigated the convergence ratio of the proposed method, which was closely related with the number of measured phase encode set and the frequency range of the background field inhomogeneity. In the phantom experiment with a partial Fourier acquisition, the total scan time was less than 6 seconds to measure the magnetic flux density Bz data with 128×128 spacial matrix size, where it required 10.24 seconds to fill the complete k-space region. CONCLUSION Numerical simulation and experimental results demonstrated that the proposed method reduces the scanning time and provides the recovered Bz data comparable to what we obtained by measuring complete k-space data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MREIT conductivity imaging of canine head using multi-echo pulse sequence

In magnetic resonance electrical impedance tomography (MREIT), we measure induced magnetic flux densities subject to multiple injection currents to reconstruct crosssectional conductivity images. Spin echo pulse sequence has been widely used in MREIT and produce postmortem and in vivo conductivity images of animal and human subjects. The image quality depends on the SNR of the measured magnetic...

متن کامل

Reconstruction of dual-frequency conductivity by optimization of phase map in MREIT and MREPT

BACKGROUND The spectroscopic conductivity distribution of tissue can help to explain physiological and pathological status. Dual frequency conductivity imaging by combining Magnetic Resonance Electrical Property Tomography (MREPT) and Magnetic Resonance Electrical Impedance Tomography (MREIT) has been recently proposed. MREIT can provide internal conductivity distributions at low frequency (bel...

متن کامل

Fast imaging for magnetic resonance electrical impedance tomography.

In magnetic resonance electrical impedance tomography (MREIT), currents are injected into an object, the resulting magnetic flux density is measured using MRI, and the conductivity distribution reconstructed using these MRI data. The relatively long acquisition times of conventional MREIT methods limit the signal averaging rate and are susceptible to motion artifacts. In this study, we reconstr...

متن کامل

Simulation of MREIT using Balanced Steady State Free Precession (b-SSFP) Pulse Sequence

Magnetic resonance electrical impedance tomography (MREIT) utilizes the relation between conductivity and magnetic flux density induced by externally injected current to perform conductivity imaging of body tissues. A spin echo pulse sequence has been predominantly used in MREIT to acquire the z-component Bz of the induced magnetic flux density data from MR phase images. Spin echo based MREIT p...

متن کامل

Fast conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) for RF ablation monitoring.

PURPOSE This study shows the potential of magnetic resonance electrical impedance tomography (MREIT) as a non-invasive RF ablation monitoring technique. MATERIALS AND METHODS We prepared bovine muscle tissue with a pair of needle electrodes for RF ablation, a temperature sensor, and two pairs of surface electrodes for conductivity image reconstructions. We used the injected current non-linear...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2013