Introduction of the Thin Prep Imaging System™ (TIS): experience in a high volume academic practice
نویسندگان
چکیده
OBJECTIVE Since the introduction of the liquid-based ThinPrep testing in 1996, most cytology laboratories across the country have adopted the liquid-based cytology (LBC) for Pap test screening. Subsequent to wide-spread adoption of the ThinPrep Pap test, the ThinPrep Imaging System (TIS) Cytyc Corp, Marlborough, MA was introduced to improve the accuracy and efficiency of screening interpretation. We report our initial experience with the TIS at Magee Women's Hospital. We introduced the TIS in December 2004. METHODS The imager assisted Pap test results over the first 12 months (December 2004 to December 2005) of implementation were reviewed and analyzed. Our implementation protocol included each cytotechnologist manually prescreening 200 negative slides to gain experience with the imager slides and serve as a quality check for the TIS. We re-screened 3400 slides (200 slides each for 17 cytotechnologists) manually which were initially determined to be negative using the TIS. 104,457 Pap tests were imaged on the TIS. 95,899 manually screened Pap tests, 12 months prior to the introduction of the TIS (December 2003-November 2004) are taken as the historic control group for our study. RESULTS The mean ASC-US rate employing the automated imager was 8.70% [9088/104,457]. The mean LSIL detection rate was 4.22% [4409/104,457]. The imager did not miss any detectable high-grade lesions during these months, with a HSIL (+) detection rate of 0.68% in comparison to 0.60% by manual screening confirmed by follow-up biopsies. The difference is statistically significant with a p value of 0.022. The definition of false negative rate for purposes of this study is calculated as the number of false negative cases identified out of number of negatives re-screened. The TIS false negative rate was estimated at 0.012% [4/3400]. CONCLUSION The overall performance of the TIS in our lab appears to be highly satisfactory in terms of improving sensitivity in screening cervical precursor lesions. The increased accuracy of detection of HSIL indicates a positive impact of the TIS in our laboratory.
منابع مشابه
مقایسه پاپ اسمیر مرسوم و اسمیر پاپانیکولائو لایه نازک بر پایه مایع تهیه شده
Background and purpose: Because of the importance of early diagnosis of cervical cancer and high false negative results of conventional smear method, several studies have been performed to find a more appropriate test in recent years. Fluid-based methods especially thin prep are considered to have the highest potential to reduce the false negative results and to increase the adequacy of speci...
متن کاملQuantification of partial volume effects in planar imaging
Introduction: The limited resolution of the imaging system causes partial volume effects (PVEs). These results in spreading of image counts to the neighboring pixels. This phenomenon is called spill-out effect. This study aimed at quantifying PVEs using ImageJ. Methods:Technetium-99m solution of concentration of 74 kBq/ml was filled into spheres A, B<...
متن کاملInstructional Design, Implementation, and Evaluation of an E-Learning System, an Experience in Tehran University of Medical Sciences
Introduction: Designing e-learning systems based on the principles and prerequisites of teaching and learning theories requires a comprehensive and systematic approach to instructional design procedure. An experience of instructional design, implementation and evaluation of an e-learning system is represented in this study. Methods: In the present action research study, five steps of systemati...
متن کاملFeasibility of using Medical Imaging Interaction Toolkit in volumetric studies to accurate diagnosing of vascular emboli by Extended NURBS-based Cardiac-Torso phantom
Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated....
متن کاملThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CytoJournal
دوره 4 شماره
صفحات -
تاریخ انتشار 2007