A proposal for a flow cytometric data file standard.
نویسندگان
چکیده
The increasing complexity of multiparameter data collection and analysis in flow cytometry and the development of relatively inexpensive arc-lamp-based flow cytometers, which increases the probability that laboratories or institutions may have more than one type of instrument, creates a need for shareable analysis programs and for the transport of flow cytometric data files within an installation or from one institution to another. To address this need, we propose a standard file format to be used for all flow cytometric data. The general principles of this proposal are: (1) The data file will contain a minimum of three segments, TEXT, DATA, and ANALYSIS; (2) The TEXT and ANALYSIS segments consist of KEYWORDS, which are the names of data fields, and their values; (3) All TEXT is encoded in ASCII; (4) KEYWORDS and their values may be of any length; (5) Certain KEYWORDS will be standard, i.e., having specified formats to be recognized by all programs. The structure of the DATA segment will be uniquely defined by the values of KEYWORDS in the TEXT area. It may be in any bit resolution, facilitating compatibility between machines with different word length and/or allowing bit compression of the data. The structured nature of the TEXT area should facilitate management of flow cytometric data using existing data base management systems. The proposed file format has been implemented on VAX, PDP-11, and HP9920 based flow cytometry data acquisition systems.
منابع مشابه
Flow Cytometric Measurement of CD41/CD61 and CD42b Platelet Receptors and Clotting Assay of Platelet Factor 3 During Long Term-Storage of Platelet Concentrates
Background: The purpose of the present in vitro study was to evaluate the effect of long term storage of conventional platelet concentrates (PCs) on major platelet receptors CD42b and CD41/CD61 by flow cytometry method and also measuring the overall platelet procoagulant activity status using platelet factor 3 (PF3) assay. Materials and Methods: Six random units of conventional platelet conce...
متن کاملFlow Cytometric Measurement of CD41/CD61, CD42b Platelet Receptors and Platelet Factor 3 Activity in Lyophilized Infusible Platelet Membrane Preparation
Background: The short life time of human platelet units has led to a chronic shortage of fresh platelets in blood transfusion centers. Many approaches have been investigated experimentally to produce new hemostatically active platelet products that are capable of long term storage. Infusible platelet membrane (IPM) prepared from fresh or outdated human platelets have been developed as an altern...
متن کاملProposed new data file standard for flow cytometry, version FCS 3.0.
In 1984, the first flow cytometry data file format was proposed as Flow Cytometry Standard 1.0 (FCS1.0). FCS 1.0 provided a uniform file format allowing data acquired on one computer to be correctly read and interpreted on other computers running a variety of operating systems. That standard was modified in 1990 and adopted by the Society of Analytical Cytology as FCS 2.0. Here, we report on an...
متن کاملDeficient Expression of Bruton's Tyrosine Kinase in Monocytes from X-Linked Agammaglobulinemia as Evaluated by a Flow Cytometric Analysis and its Clinical Application to Carrier Detection
Background: The B-cell defect in X-linked agammaglobulinemia (XLA) is caused by mutations in the gene for Bruton's tyrosine kinase (BTK). BTK mutations result in deficient expression of BTK protein in peripheral blood monocytes. Methods: Using the anti-BTK monoclonal antibody (48-2H), a flow cytometric analysis of intra cytoplasmic BTK protein expression in monocytes was performed to identify I...
متن کاملComparison of Two Flow Cytometric Methods for Detection of Human Invariant Natural Killer T Cells (iNKT)
Background: Invariant natural killer cells (iNKT) are an important immunoregulatory T cell subset. Currently several flow cytometry-based approaches exist for the identifi-cation of iNKT cells, which rely on using the 6B11 monoclonal antibody or a combina-tion of anti-Vα24 and anti-Vβ11 antibodies. Objective: The aim of this study was to compare the ability of two flow cytometry-based methods f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cytometry
دوره 5 5 شماره
صفحات -
تاریخ انتشار 1984