INTRODUCTION The objective of this study was to assess tracheal reactivity after the deployment of different self-expandable metal stents (SEMS). MATERIAL AND METHODS Forty female New Zealand rabbits were divided into four groups. Three groups received three different SEMS: steel (ST), nitinol (NiTi), or nitinol drug-eluting stent (DES); the fourth group was the control group (no stent). Stents were deployed percutaneously under fluoroscopic guidance. Animals were assessed by multi-slice, computed tomography (CT) scans, and tracheas were collected for anatomical pathology (AP) study. Data from CT and AP were statistically analyzed and correlated. RESULTS The DES group had the longest stenosis (20.51±14.08mm vs. 5.84±12.43 and 6.57±6.54mm in NiTi and ST, respectively, day 30; P<.05), and higher granuloma formation on CT (50% of cases). The NiTi group showed the lowest grade of stenosis (2.86±6.91% vs. 11.28±13.98 and 15.54±25.95% in DES and ST, respectively; P<.05). The AP study revealed that the ST group developed intense proliferative reactivity compared to the other groups. In the DES group, a destructive response was observed in 70% of the animals, while the NiTi was the least reactive stent. CT was more effective in detecting wall thickening (positive correlation of 68.9%; P<.001) than granuloma (not significant). CONCLUSIONS The ST group developed granulomas and significant stenosis. NiTi was the least reactive stent, while DES caused significant lesions that may be related to drug dosage. This type of DES stent is therefore not recommended for the treatment of tracheobronchial stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of covered and uncovered self-expandable stents in the treatment of malignant biliary obstruction.

BACKGROUND AND OBJECTIVE Drainage with metallic stents is the treatment of choice in malignant obstructive jaundice. Technical and clinical success with metallic stents is obtained in over 90% and 80% of cases, respectively. There are self-expandable metallic stents designed to increase permeability. The aim of this study was to describe the results obtained with totally covered self-expandable...

متن کامل

Balloon-expandable Metallic Stents for Airway Diseases.

Stent placement is an essential treatment for airway diseases. Although self-expandable metallic stents and silicone stents are commonly applied for the treatment of airway diseases, these stents are unsuitable for the treatment of small airway diseases encountered in pediatric patients and lung transplant recipients with airway complications. Currently, only vascular balloon-expandable metalli...

متن کامل

Metallic expandable stents in the management of malignant tracheal stenosis due to esophageal cancer with lymph node metastasis

Esophageal cancer with post-operative lymph node metastasis (LNM) compressing and infiltrating the trachea causing dyspnea is considered a serious complication. However, chemotherapy or radiotherapy are often ineffective methods for such patients. Approaches employing metallic expandable stents to relieve airway obstruction are extremely effective in advanced-stage cancer patients. The present ...

متن کامل

Management of airway manifestations of relapsing polychondritis: case reports and review of literature.

STUDY OBJECTIVE To report the first series of patients with severe airway manifestations of relapsing polychondritis (RP) that were managed successfully with self-expandable metallic stents, and to review the literature. DESIGN Retrospective review of medical records, and current clinical follow-up. SETTING Tertiary care referral hospital. PATIENTS All patients with airway manifestations ...

متن کامل

Evaluation of a new self-expandable silicone stent in an experimental tracheal stenosis.

STUDY OBJECTIVES To assess the usefulness of an animal model for testing new tracheobronchial stents. SETTING Animal laboratory of a university hospital. ANIMALS AND INTERVENTIONS In a series with 12 mini-pigs, we induced a stable fibromalacic tracheal stenosis that was 50% to 70% of the normal tracheal diameter. After dilation we inserted a 16 x 40-mm self-expandable silicone stent into th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de bronconeumologia

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2016