Particle Depositions and Related Hemodynamic Parameters in the Multiple Stenosed Right Coronary Artery

نویسندگان

  • Sandor I. Bernad
  • Elena S. Bernad
  • Marius Craina
  • Izabella Sargan
  • Alin Totoran
  • Cosmin Brisan
چکیده

BACKGROUND Blood flow analysis of the human right coronary artery (RCA) has been carried out to investigate the effects of serial stenosis on coronary hemodynamics. A 3-D model of a serial stenosed RCA was reconstructed based on multislice computerized tomography images. METHODS A velocity waveform in the proximal RCA and a pressure waveform in the distal RCA of a patient with a severe stenosis were acquired with a catheter delivered wire probe and applied as boundary conditions. The numerical analysis examines closely the effect of a multiple serial stenosis on the hemodynamic characteristics such as flow separation, wall shear stress (WSS) and particle depositions. RESULTS AND CONCLUSIONS Energy loss associated with such flow expansion after each constriction will be large and consequently the pressure drop will be higher. Overall pressure drop increased from 1700 Pa (12.75 mmHg) at the end diastole to 11000 Pa (82.5 mmHg) at the peak systole. At the peak systole the WSS values reached 110 Pa in the stenosis with 28% diameter reduction and 210 Pa in the stenosis with 54% diameter reduction, which is high enough to damage the endothelial cells. However at the end of one cardiac cycle a percent of 1.4% (15 from 1063 particles release at the inlet section) remain inside the stenosed RCA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

The effect of cardiac rehabilitation on hemodynamic status in patients after coronary artery bypass surgery

Background: Today, coronary artery bypass graft surgery (CABG) in many patients is commonly used to treat complications of the disease. Aim: This study aimed to evaluate the impact of cardiac rehabilitation on hemodynamic parameters in patients undergoing CABG. Methods: : In this clinical trial which was conducted in Rajaee Hospital of Tehran University of Medical Sciences 100 patients after co...

متن کامل

Numerical modeling of the flow in stenosed coronary artery. The relationship between main hemodynamic parameters

The severity of coronary arterial stenosis is usually measured by either simple geometrical parameters, such as percent diameter stenosis, or hemodynamically based parameters, such as the fractional flow reserve (FFR) or coronary flow reserve (CFR). The present study aimed to establish a relationship between actual hemodynamic conditions and the parameters that define stenosis severity in the c...

متن کامل

Hemodynamic changes and related factors in patients undergoing coronary artery ‎bypass grafting surgery

Introduction: Coronary artery diseases are the primary and most common cause of death in all ages. ‎Coronary artery bypass grafting (CABG) surgery as a common treatment intervention is considered ‎necessary in patients with coronary artery disease. Complications may occur during and after ‎‎(CABG) surgery. Among major complications are hemodynamic changes after surgery which is ...

متن کامل

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012