Preliminary investigation of residual-limb fluid volume changes within one day.
نویسندگان
چکیده
The purpose of this research was to investigate rates of residual-limb fluid volume change within one day for people with transtibial limb loss. Rates of fluid volume change during 30 min test sessions of sitting, standing, and walking activities were measured twice a day, once in the morning and once in the afternoon, on 12 regular prosthesis users with the use of bioimpedance analysis. Between test sessions, all subjects consumed food and drink, and subject activity ranged from low to high. The rate of fluid volume change within sessions ranged from -8.5 to 5.9 %/h (median: -2.2%/h). The rate of fluid volume change between sessions ranged from -2.7 to 0.9 %/h (median: -1.0%/h). The between-session rate of fluid volume change correlated highly with afternoon within-session rates of change (r = 0.9) but was not well correlated with morning within-session rates of change (r = 0.8). Subjects with peripheral arterial complications showed greater fluid volume loss rates during test sessions than between sessions. Rate of fluid volume change may be affected by sitting, standing, and walking activities; presence of peripheral arterial complications; being female; time since amputation; and wearing the socket without doffing for extended periods.
منابع مشابه
Preliminary evaluation of a novel bladder-liner for facilitating residual limb fluid volume recovery without doffing.
For people who wear a prosthetic limb, residual-limb fluid volume loss during the day may be problematic and detrimentally affect socket fit. The purpose of this research was to test the capability of a novel liner with adjustable bladders positioned within its wall to mitigate volume loss and facilitate limb fluid volume recovery and retention. Bioimpedance analysis was used to monitor fluid v...
متن کاملShape and volume change in the transtibial residuum over the short term: preliminary investigation of six subjects.
A preliminary investigation was conducted to characterize the magnitude and distribution of volume change in transtibial residua at two time intervals: upon prosthesis removal and at 2 week intervals. Six adult male unilateral transtibial amputee subjects, between 0.75 and 40.0 years since amputation, were imaged 10 times over a 35-minute interval with a custom residual limb optical scanner. Vo...
متن کاملHow do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?
The purpose of this research was to investigate the influence of sock addition and removal on residual-limb fluid volume in people using prosthetic limbs. We used bioimpedance analysis to measure residual-limb extracellular fluid volume on 28 transtibial amputee subjects during 30 min test sessions. Upon addition of a one-ply polyester sock, residual-limb fluid volume changes ranged from -4.0% ...
متن کاملEffects of elevated vacuum on in-socket residual limb fluid volume: case study results using bioimpedance analysis.
Bioimpedance analysis was used to measure the residual limb fluid volume of seven transtibial amputee subjects using elevated vacuum sockets and nonelevated vacuum sockets. Fluid volume changes were assessed during sessions with the subjects sitting, standing, and walking. In general, fluid volume losses during 3 or 5 min walks and losses over the course of the 30 min test session were less for...
متن کاملHow do walking, standing, and resting influence transtibial amputee residual limb fluid volume?
The purpose of this research was to determine how fluid volume changes in the residual limbs of people with transtibial amputation were affected by activity during test sessions with equal durations of resting, standing, and walking. Residual limb extracellular fluid volume was measured using biompedance analysis in 24 participants. Results showed that all subjects lost fluid volume during stan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of rehabilitation research and development
دوره 49 10 شماره
صفحات -
تاریخ انتشار 2012