Two-Year Results of an Open-Label Randomized Comparison of Everolimus-Eluting Stents and Sirolimus-Eluting Stents
نویسندگان
چکیده
BACKGROUND Second generation drug-eluting stents were developed to improve the safety and efficacy of first generation stents. So far, limited long term randomized data exist comparing the second generation everolimus-eluting stents (EES) with first generation sirolimus-eluting stents (SES). METHODS A prospective, open-label, randomized, single center trial comparing EES and SES in all-comer patients. The primary endpoint was a composite of cardiac mortality, myocardial infarction and target vessel revascularization. Secondary endpoints included individual components of the composite, along with target lesion revascularization and stent thrombosis. RESULTS In total, 977 patients were randomized, of which 498 patients to EES and 479 to SES. Average age was 65.2 ± 11.2 years and 71.6% of the population was male. Fifty percent of patients were treated for acute coronary syndrome, more often for ST-elevation myocardial infarctions in EES patients (13.7% vs. 9.2% in SES). In contrast, SES patients more often had prior interventions and showed more calcified lesions. Two-year follow-up was available in 98% of patients. The primary endpoint occurred in 10.7% of EES patients compared to 10.6% of SES patients (HR 1.00, 95% CI 0.68-1.48). Additionally, secondary endpoints were similar between groups. The rate of stent thrombosis was low for both stent types. CONCLUSION In this all-comer population, there were no differences in endpoints between EES and SES during two-year follow-up. Stent thrombosis rates were low, supporting the safety of drug-eluting stent appliance in clinical practice. TRIAL REGISTRATION TrialRegister.nl NTR3170.
منابع مشابه
Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS
Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...
متن کاملInterventional Cardiology Randomized Comparison of Everolimus-Eluting Stent Versus Sirolimus-Eluting Stent Implantation for De Novo Coronary Artery Disease in Patients With Diabetes Mellitus (ESSENCE-DIABETES) Results From the ESSENCE-DIABETES Trial
Background—Drug-eluting stents significantly improved angiographic and clinical outcomes compared with bare metal stents in diabetic patients. However, a comparison of everolimus-eluting stents and sirolimus-eluting stents in diabetic patients has not been evaluated. Therefore we compared effectiveness of everolimus-eluting stents and sirolimus-eluting stents in patients with diabetes mellitus....
متن کاملThree-year follow-up of patients with bifurcation lesions treated with sirolimus- or everolimus-eluting stents: SEAside and CORpal cooperative study.
INTRODUCTION AND OBJECTIVES To compare the 3-year incidence of major events in patients with bifurcation lesions treated with provisional sirolimus-eluting stents vs everolimus-eluting stents. METHODS A pooled analysis of 2 prospective randomized trials with similar methodology (SEAside and CORpal) was performed. In these trials, 443 patients with bifurcation lesions were randomly assigned to...
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کاملComparison of Everolimus-Eluting and Sirolimus-Eluting Coronary Stents: 1-Year Outcomes from the Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial (RESET) Running title: Kimura et al.; Everolimus-eluting versus Sirolimus-eluting stents
Takeshi Kimura, MD; Takeshi Morimoto, MD; Masahiro Natsuaki, MD; Hiroki Shiomi, MD; Keiichi Igarashi, MD; Kazushige Kadota, MD; Kengo Tanabe, MD; Yoshihiro Morino, MD; Takashi Akasaka, MD; Yoshiki Takatsu, MD; Hideo Nishikawa, MD; Yoshito Yamamoto, MD; Yoshihisa Nakagawa, MD; Yasuhiko Hayashi, MD; Masashi Iwabuchi, MD; Hisashi Umeda, MD; Kazuya Kawai, MD; Hisayuki Okada, MD; Kazuo Kimura, MD; C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013