Stabilities of quantitative plasma culture for human immunodeficiency virus, RNA, and p24 antigen from samples collected in VACUTAINER CPT and standard VACUTAINER tubes.

نویسندگان

  • L Mole
  • D Margolis
  • R Carroll
  • J Todd
  • M Holodniy
چکیده

We evaluated the stability of human immunodeficiency virus (HIV) load markers from blood samples collected in VACUTAINER CPT or standard VACUTAINER brand tubes using sodium heparin or sodium citrate as anticoagulants. Quantitative plasma culture and p24 antigen concentrations were determined, and HIV RNA levels in plasma were measured by both reverse transcription-PCR-enzyme-linked immunosorbent assay (RT-PCR-ELISA) and branched DNA methods. All tubes were stored at room temperature for analysis at 2, 24, 48, and 72 h after the blood samples were drawn. No difference was seen between tube types with respect to the HIV titer in plasma or the positivity rate for all samples that demonstrated a fall in titer over time. Unbound p24 antigen levels in plasma decreased during the initial 48-h period in both tube types. Immune complex-dissociated p24 antigen levels decreased in CPT tubes but not in standard VACUTAINER tubes. The HIV RNA copy number in plasma measured by RT-PCR-ELISA was stable in most subjects and was significantly higher in CPT tubes than in standard VACUTAINER tubes at 24 and 72 h after the blood samples were drawn. The branched DNA probe assay detected a significant decline in HIV RNA equivalent in plasma over 72 h in both collection tubes, the decline being more dramatic in the standard VACUTAINER tube than the CPT tube. Overall, interday variability suggests that samples collected for a particular assay should be processed at the same time after blood is drawn and that a particular tube type be used throughout a given study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of specimen collection, processing, and storage conditions on stability of human immunodeficiency virus type 1 RNA levels in plasma.

To define the optimal blood collection parameters for plasma human immunodeficiency virus type 1 (HIV-1) viral load testing, plasma HIV-1 RNA levels were quantitated with the NASBA HIV-1 RNA QT System from blood specimens that were collected, processed, and stored under a variety of conditions that might have affected HIV-1 RNA stability. We determined that when whole blood was processed within...

متن کامل

Evaluation of the VACUTAINER Brand PPTTM Tubes for HCV Viral Load Testing

We investigated the performance of a new collection tube for the preparation of EDTA anti-coagulated plasma for viral load testing. HCV RNA copy numbers were measured with a commercially available assay (the Amplicor HCV MonitorTM test kit). Blood specimens were collected from HCV-seropositive individuals in the VACUTAINER Brand Plasma Preparation TubeTM and a control, non-gel separator VACUTAI...

متن کامل

Stability of plasma human immunodeficiency virus load in VACUTAINER PPT plasma preparation tubes during overnight shipment.

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas obtained from PPT tubes stored and shipped under nine different conditions were compared to conventional EDTA tube plasmas stored at -70 degrees C within 2 h after phlebotomy. Compared to viral loads...

متن کامل

Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays.

We investigated the use of serum samples from BD Vacutainer rapid serum tubes (RSTs; BD, Franklin Lakes, NJ) to reduce undetermined interferences contributing to false-positive immunoassay results in heparin plasma samples. Patients being evaluated for suspected myocardial infarction had specimens drawn into an RST in addition to the standard lithium-heparin plasma separator tube (PST). We meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 32 9  شماره 

صفحات  -

تاریخ انتشار 1994