Agreement between the Takeda UA-731 automatic blood pressure measuring device and the manual mercury sphygmomanometer: an assessment under field conditions in Newcastle upon Tyne, UK.
نویسندگان
چکیده
STUDY OBJECTIVE To assess agreement between two Takeda UA-731 automatic blood pressure measuring devices (referred to as machines A and B) and two manual mercury sphygmomanometers. DESIGN A 'Y' connector attached each Takeda UA-731 to a manual mercury sphygmomanometer. Simultaneous measurements were made on adult subjects. SETTING A population based cardiovascular disease survey in Newcastle upon Tyne, UK. PARTICIPANTS Measurements on machine A were compared in 71 individuals (all women), and on machine B in 75 individuals (9 men, 66 women). The age range of subjects was 28 to 76 years and median ages were 59 years for machine A and 50 years for machine B. MAIN RESULTS Blood pressure (mmHg) ranged from 72 to 212 systolic and 44 to 102 diastolic. Both Takedas gave significantly lower readings than the manual devices for systolic and diastolic pressures: differences were mean (SD: 95% CI) 3.7 mmHg (6.5: 2.2, 5.2) for machine A systolic, 2.3 mmHg (4.5: 1.3, 3.4) machine A diastolic; 1.8 mmHg (6.2: 0.4, 3.3) machine B systolic, and 1.8 (4.4: 0.8, 2.8) machine B diastolic. On the British Hypertension Society criteria, machine A was graded C on systolic measurements and B on diastolic; machine B was graded B on both systolic and diastolic measurements. CONCLUSIONS The performance of these machines compares favourably with the Dinamap 8100, recently adopted for survey work by the Department of Health. The Takeda UA-731 looks promising for epidemiological survey work but before it can be fully recommended further evaluations are needed.
منابع مشابه
مقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی
Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...
متن کاملMeasuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors?
OBJECTIVES To compare the agreement between conventional measurement of blood pressure and measurements obtained using two automated devices; and to compare how comfortable each of the three methods of measurement were for patients. METHODS Blood pressure measurements and patient comfort scores were recorded using three different devices in 125-surgery and 40-community patients. The devices u...
متن کاملAssessing agreement of blood pressure-measuring devices in Tibetan areas of China: a systematic review
BACKGROUND The validity of blood pressure (BP)-measuring tools at very high altitudes is uncertain. Therefore, the objective of this review was to examine the degree of agreement of BP-measuring devices in Tibet. METHODS We conducted electronic searches in Medline, Embase, Cinahl, Cochrane Library, Global Health Library and the ISI Web of Science. Randomised and observational studies were con...
متن کاملComparison of the automated Dinamap blood pressure monitor with the mercury sphygmomanometer for detecting hypertension in the day case pre-assessment clinic
Patients will be rejected from surgery by nurse-led pre-assessment clinics and will need to be assessed by their general practitioners if their blood pressure is higher than a pre-determined value. We have assessed the accuracy of the Dinamap automatic blood pressure recorder compared with manual mercury sphygmomanometry for detecting pre-operative hypertension in the day case preassessment cli...
متن کاملComparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of epidemiology and community health
دوره 50 2 شماره
صفحات -
تاریخ انتشار 1996