Bispectral index monitoring during electroconvulsive therapy under propofol anaesthesia.

نویسندگان

  • P O Gunawardane
  • P A Murphy
  • J W Sleigh
چکیده

BACKGROUND The accuracy of the bispectral index (BIS) as a monitor of consciousness has not been well studied in patients who have abnormal electroencephalograms (EEG). METHODS We studied the changes in BIS, its subparameters, and spectral entropy of the EEG during 18 electroconvulsive treatments under propofol and succinylcholine anaesthesia. A single bifrontal EEG, and second subocular channel (for eye movement estimation) was recorded. RESULTS The median (interquartile range) BIS value at re-awakening was only 57 (47-78)--thus more than a quarter of the patients woke at BIS values of less than 50. The changes in spectral entropy values were similar: 0.84 (0.68-0.99) at the start, 0.65 (0.42-0.88) at the point of loss-of-consciousness, 0.63 (0.47-0.79) during the seizures, and 0.58 (0.31-0.85) at awakening. CONCLUSIONS Post-ictal slow-wave activity in the EEG (acting via the SynchFastSlow subparameter) may cause low BIS values that do not correspond to the patient's clinical level of consciousness. This may be important in the interpretation of the BIS in other groups of patients who have increased delta-band power in their EEG.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Utility of Bispectral Index for Titration of Propofol Dosages and Recovery from Anaesthesia

Background: The use of clinical signs may not be reliable to measure the hypnotic component of anaesthesia. Bispectral Index monitoring provides a direct measurement of the hypnotic effect of the anaesthetic agent used and it may have certain clinical advantages over clinical signs. Objective: This study consists of dose requirement of propofol with bispectral Index monitoring and without bispe...

متن کامل

Bilateral bispectral index monitoring during and after electroconvulsive therapy compared with magnetic seizure therapy for treatment-resistant depression.

BACKGROUND Electroconvulsive therapy (ECT) is a highly effective and established treatment for depression. Magnetic seizure therapy (MST) has recently been developed and seems equally effective while associated with fewer side-effects. Both require general anaesthesia, which could be quantified using the bispectral index (BIS). We compared ECT and MST with respect to recovery times, left-sided ...

متن کامل

Monitoring of the responsiveness to noxious stimuli during anaesthesia with propofol and remifentanil by using RIII reflex threshold and bispectral index.

BACKGROUND Movement responses are an important indicator of noxious perception in the unconscious state. To allow for a continual monitoring of the responsiveness to noxious stimuli during general anaesthesia, surrogate parameters are needed. Here we compare the performance of the bispectral index (BIS) and the RIII threshold in predicting reactions to noxious stimuli during anaesthesia with pr...

متن کامل

Comparison of bispectral EEG analysis and auditory evoked potentials for monitoring depth of anaesthesia during propofol anaesthesia.

We have compared the auditory evoked potential index (AEPIndex) and bispectral index (BIS) for monitoring depth of anaesthesia in spontaneously breathing surgical patients. Twenty patients (aged 17-49 yr) undergoing day surgery were anaesthetized with computer-controlled infusions of propofol. The mean (SD and range) of each measurement was determined during consciousness and unconsciousness an...

متن کامل

EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recovery.

BACKGROUND Recent studies have suggested that electroencephalogram (EEG) bispectral index (BIS) monitoring can improve recovery after anaesthesia and save money by shortening patients' postoperative stay. We wanted to evaluate the direct costs of BIS monitoring and to measure immediate recovery after anaesthesia in patients with or without BIS monitoring. METHODS Eighty patients undergoing gy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 88 2  شماره 

صفحات  -

تاریخ انتشار 2002