Dead-end filling of SlipChip evaluated theoretically and experimentally as a function of the surface chemistry and the gap size between the plates for lubricated and dry SlipChips.

نویسندگان

  • Liang Li
  • Mikhail A Karymov
  • Kevin P Nichols
  • Rustem F Ismagilov
چکیده

In this paper, we describe a method to load a microfluidic device, the SlipChip, via dead-end filling. In dead-end filling, the lubricating fluid that fills the SlipChip after assembly is dissipated through the gap between the two plates of the SlipChip instead of flowing through an outlet at the end of the fluidic path. We describe a theoretical model and associated predictions of dead-end filling that takes into consideration the interfacial properties and the gap size between plates of SlipChips. In this method, filling is controlled by the balance of pressures: for filling to occur without leaking, the inlet pressure must be greater than the capillary pressure but less than the maximum sealing pressure. We evaluated our prediction with experiments, and our empirical results agreed well with theory. Internal reservoirs were designed to prevent evaporation during loading of multiple solutions. Solutions were first loaded one at a time into inlet reservoirs; by applying a single pressure source to the device, we were able to fill multiple fluidic paths simultaneously. We used this method to fill both lubricated and dry SlipChips. Dry-loaded SlipChips were fabricated from fluorinated ethylene propylene (FEP) by using hot embossing techniques, and were successfully filled and slipped to perform a simple chemical reaction. The SlipChip design was also modified to enable ease of filling by using multiple access holes to the inlet reservoir.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Supporting Information for Dead-end filling of SlipChip evaluated theoretically and experimentally as a function of the surface chemistry and the gap size between the plates for lubricated and dry SlipChips

Experimental Section: Fabrication of glass devices The procedure for fabrication of SlipChip from glass was based on previous work. 1 The sodalime glass slide with chromium and photoresist coating was aligned with a photomask containing the design for the wells and the ducts, and AZ 1500 positive photoresist was exposed using standard exposure protocols. The glass plate was immersed in 0.1 mol/...

متن کامل

Application of the method of multiple scales for nonlinear vibration analysis of mechanical systems with dry and lubricated clearance joints

In this study, the method of multiple scales is used to perform a nonlinear vibration analysis of a mechanical system in two cases; with dry and lubricated clearance joints. In the dry contact case, the Lankarani-Nikravesh model is used to represent the contact force between the joined bodies. The surface elasticity is modeled as a nonlinear spring-damper element. Primary resonance is discussed...

متن کامل

A Comparative Investigation of Marginal Adaptation and Surface Defects of MTA and Root MTA as Two Root End Filling Materials

Introduction: This study was carried out to compare two retrograde filling materials entitled mineral trioxide aggregate (MTA) and Root MTA (RMTA) in regard to their marginal adaptation and surface defects. Method: In this study twenty extracted human teeth were used. In all teeth after cleaning and shaping, the root canals were obturated by gutta-percha and root canal sealer. After that in eac...

متن کامل

SlipChip for immunoassays in nanoliter volumes.

This article describes a SlipChip-based approach to perform bead-based heterogeneous immunoassays with multiple nanoliter-volume samples. As a potential device to analyze the output of the chemistrode, the performance of this platform was tested using low concentrations of biomolecules. Two strategies to perform the immunoassay in the SlipChip were tested: (1) a unidirectional slipping method t...

متن کامل

User-loaded SlipChip for equipment-free multiplexed nanoliter-scale experiments.

This paper describes a microfluidic approach to perform multiplexed nanoliter-scale experiments by combining a sample with multiple different reagents, each at multiple mixing ratios. This approach employs a user-loaded, equipment-free SlipChip. The mixing ratios, characterized by diluting a fluorescent dye, could be controlled by the volume of each of the combined wells. The SlipChip design wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Langmuir : the ACS journal of surfaces and colloids

دوره 26 14  شماره 

صفحات  -

تاریخ انتشار 2010