Performance of an implantable automatic atrial fibrillation detection device: impact of software adjustments and relevance of manual episode analysis

نویسندگان

  • Charlotte Eitel
  • Daniela Husser
  • Gerhard Hindricks
  • Manuela Frühauf
  • Sebastian Hilbert
  • Arash Arya
  • Thomas Gaspar
  • Ulrike Wetzel
  • Andreas Bollmann
  • Christopher Piorkowski
چکیده

AIMS Implantable loop recorders (ILRs) with specific atrial fibrillation (AF) detection algorithms (ILR-AF) have been developed for continuous AF monitoring. We sought to analyse the clinical value of a new AF monitoring device and to compare it to serial 7-day Holter. METHODS AND RESULTS Sixty-four consecutive patients suffering from paroxysmal AF were included in this prospective analysis and received an ILR-AF. Manual electrogram analysis was performed for each automatically detected episode and each was categorized into one of three possible diagnoses: 'no AF', 'definite AF', and 'possible AF' (non-diagnostic). Analysis was performed separately before and after a software upgrade that was introduced during the course of the study. A subgroup of patients (51 of 64) underwent AF catheter ablation with subsequent serial 7-day Holter in comparison with the ILR-AF. A total of 333 interrogations were performed (203 before and 130 after software upgrade). The number of patients with AF misdetection was significantly reduced from 72 to 44% following the software upgrade (P = 0.001). The number of patients with non-diagnostic interrogations went from 38 to 16% (P = 0.001). Compared with serial 7-day Holter, the ILR-AF had a tendency to detect a higher number of patients with AF recurrences (31 vs. 24%; P = 0.125). CONCLUSIONS The rate of AF detection on ILR-AF may be higher compared with standard AF monitoring. However, false-positive AF recordings hamper the clinical value. Developments in device technology and device handling are necessary to minimize non-diagnostic interrogations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators

AIMS The Secura ICD and Consulta CRT-D are the first defibrillators to have automatic right atrial (RA), right ventricular (RV), and left ventricular (LV) capture management (CM). Complete CM was evaluated in an implantable cardioverter defibrillator (ICD) population. METHODS AND RESULTS Two prospective clinical studies were conducted in 28 centres in Europe and Israel. Automatic CM data were...

متن کامل

Software-based detection of atrial fibrillation in long-term ECGs.

BACKGROUND Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investiga...

متن کامل

Arrhythmias in Patients With Pulmonary Hypertension; A Narrative Review of the Current Literature

Incidence and prognostic relevance of supraventricular arrhythmias were evaluated in nine studies. These studies investigated patients with different forms of pulmonary hypertension. Supraventricular arrhythmias were more often found in patients with group two pulmonary hypertension. Common findings in these patients were elevated right atrial pressure and diameters and reduced tricuspid annula...

متن کامل

Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial.

BACKGROUND Current methods for detecting atrial fibrillation (AF) have limited diagnostic yield. Continuous monitoring with automatic arrhythmia detection and classification may improve detection of symptomatic and asymptomatic AF and subsequent patient treatment. The study purpose was to quantify the performance of the first implantable leadless cardiac monitor (ICM) with dedicated AF detectio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011