Optical refrigeration to 119 K, below National Institute of Standards and Technology cryogenic temperature.

نویسندگان

  • Seth D Melgaard
  • Denis V Seletskiy
  • Alberto Di Lieto
  • Mauro Tonelli
  • Mansoor Sheik-Bahae
چکیده

We report on bulk optical refrigeration of Yb:YLF crystal to a temperature of ~124 K, starting from the ambient. This is achieved by pumping the E4-E5 Stark multiplet transition at ~1020 nm. A lower temperature of 119±1 K (~-154C) with available cooling power of 18 mW is attained when the temperature of the surrounding crystal is reduced to 210 K. This result is within only a few degrees of the minimum achievable temperature of our crystal and signifies the bulk solid-state laser cooling below the National Institute of Standards and Technology (NIST)-defined cryogenic temperature of 123 K.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Mathematical Method and Thermodynamic Approaches to Design Multi-Component Refrigeration used in Cryogenic Process Part II: Optimal Arrangement

  A refrigeration cycle is a chain of various pieces of equipment including compressors, condensers, evaporators, and expansion devices each of which takes on a particular thermodynamic process duty in the cycle that eventually results in the production of the required refrigeration. The results of optimized mixed refrigerant cycles (MRCs) in Part I show that the configuration of MRC is an eff...

متن کامل

Mathematical Method and Thermodynamic Approaches to Design Multi-Component Refrigeration Used in Cryogenic Process Part I: Optimal Operating Conditions

Abstract: Minimizing the work consumed in refrigeration system is the most effective measure to reduce the cost of products in sub-ambient chemical processes. The introduction of mixed working fluids into refrigeration system in place of pure working fluids is a recent advancement applied in the field. Due to the lack of systematic design method for Mixed Refrigerant Cycle (MRC), conventional a...

متن کامل

Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility

National Institute of Standards and Technology, Gaithersburg, MD 20899-0001 The Low Background Infrared Calibration Facility (LBIR) at the National Institute of Standards and Technology has been in operation for calibration measurements of ihe radiant power emitted fn>rn infrared radiation (IR) sources, such as cryogenic blaclcbodies, for more than 2 years. The IR sources arc sent to NIST by Cu...

متن کامل

Optimal Synthesis of a Cascade Refrigeration System of LNG Through MINLP Model for Pure Refrigerant Cycles

 liquefied natural gas (LNG) is the most economical way of transporting natural gas (NG) over long distances. Liquefaction of NG by using vapor compression refrigeration system requires high operating and capital cost. Due to lack of systematic design methods for multistage refrigeration cycles, the conventional approaches of determining optimal cycle configuration are mostly based on trial-an...

متن کامل

Thermal Design Considerations and Performance Evaluation of Cryogenic Tube in Tube Heat Exchangers

Heat exchangers are the most important equipment in refrigeration processes. Design and modeling of heat exchangers operating at low temperatures are different from other regular heat exchangers. This study includes two sections. In the first section, design and modeling considerations needed for evaluating the real thermal behavior of heat exchangers at low temperatures were discussed. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 38 9  شماره 

صفحات  -

تاریخ انتشار 2013