[Tricuspid stenosis after pacemaker implantation without evidence of bacterial endocarditis. A case report].

نویسندگان

  • Carmen Garrote
  • María Luisa Fidalgo
  • Ignacio Iglesias-Garriz
  • Félix Corral
  • Jorge Silvestre
  • Ramón García-Calabozo
چکیده

Tricuspid stenosis related to endocardial pacemaker leads is uncommon. We report the case of a patient with severe tricuspid stenosis documented 15 years after the implantation of a permanent DDD pacemaker for symptomatic congenital heart block. The atrial and ventricular leads both had a loop at the level of the tricuspid valve that may have caused endothelial damage and, eventually, tricuspid stenosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report

Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...

متن کامل

Cardiac pacing in a patient with mechanical tricuspid valve.

89 coaptation, the patient was scheduled for tricuspid valve annuloplasty with concurrent implantation of an epicardial ventricular lead and pacemaker. The operation was preceded by the transvenous extraction of the old ventricular lead. Due to advanced tricuspid valve lesions, a decision was made during surgery to perform artificial tricuspid valve implantation (Medtronic ATS 33 mm). Simultane...

متن کامل

TRlCUSPl D VALVE SUBACUTE BACTERIAL ENDOC

This report records for the first time the occurrence of isolated subacute bacterial endocarditis involving the tricuspid valve in a patient whose condition evolved into classic tetralogy of Fallot, and who required prosthetic replacement of the valve in addition to surgical therapy for the congenital lesions. Postoperative complete heart block was corrected with implantation of a P-wave synchr...

متن کامل

Complete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report

Background: Neonatal lupus erythematosus is an uncommon disease. Congenital complete heart block (CCHB) usually happens in neonates with maternal systemic lupus erythematosus. The most prevalent presentation of CCHBis bradycardiathatcanbediagnosed through an electrocardiogram. Case report: Here in, we present the case of a full-term male neonate with gestational age of 37 weeks and birth weigh...

متن کامل

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 55 9  شماره 

صفحات  -

تاریخ انتشار 2002