Long-term performance of a hand held spirometer.

نویسندگان

  • A Dirksen
  • F Madsen
  • O F Pedersen
  • A M Vedel
  • A Kok-Jensen
چکیده

BACKGROUND A study was undertaken to test the long term performance of a small hand held spirometer for self-administered serial spirometric testing. METHODS Thirty turbine pocket spirometers (MicroMedical DiaryCard) were used in a clinical trial on 22 emphysematous patients with severe alpha 1-antitrypsin deficiency. The spirometers were able to store the date, time, forced expiratory volume in one second (FEV1), forced vital capacity (FVC), peak expiratory flow (PEF), and flow-volume loop for each blow. Every four weeks when the patients came for alpha 1-antitrypsin infusions the performance of their spirometer was checked before and after retrieval of the data from the spirometer. Calibration checks were threefold and included volume calibration with a 1.0 litre and 3.0 litre syringe, and flow calibration with a decompression calibrator. RESULTS After two years of study the mean number of spirometric recordings performed per spirometer was 693 (range 237-1178), and the mean number of calibration checks was 33 (range 2-57). The coefficient of variation of the calibration signal was 1-2% for syringes and 0.5-1% for the decompression calibrator. The bearings of one turbine exhibited excessive friction after 17 months. None of the other 29 instruments showed drift, and a general drift of all spirometers towards larger or smaller readings could not be shown. However, unforeseen problems in the stability of the calibrating devices were observed. CONCLUSIONS The small hand held turbine spirometers are suitable for long term patient-administered serial spirometric testing. The two year durability is acceptable and the long term reproducibility excellent.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a new electronic spirometer: the vitalograph "Escort" spirometer.

BACKGROUND The "Escort" spirometer is a lightweight, hand held spirometer employing a Fleisch pneumotachograph. Measurements of forced expiratory volume in one second (FEV1), forced vital capacity (FVC), and peak expiratory flow (PEF) are obtained from a single FVC manoeuvre. Results are displayed on a small liquid crystal display, but there is no graphical display. The performance of the Escor...

متن کامل

Free Cash Flow, Institutional Ownership and Long-Term Performance

Performance appraisal is a process which help shareholders make informed and optimal investment decisions. In recent decades, a long stream of research has devoted particular attention to the importance and impact of financial decisions on firm performance and firm value. The present study thus is primarily concerned with investigating the association between free cash flow and institutional ow...

متن کامل

The effect of intrahippocampal microinjection of Naloxone on short –term and long-term memory in adult male rats

Introduction:The hippocampus is one for the major centers of learning and memory. Role of the opioid system has been investigated and on the other hand receptors related to this system such as mu-opioid receptors (MOR) are extended in the hippocampus. In this study the effect of Naloxone administration as a mu opioid receptor antagonist on passive avoidance memory in adult male rats was i...

متن کامل

Underpricing, Ownership and Liquidity of Initial Public Offers (IPO) and Their Impact on Performance of IPO Stocks in Equity Markets of India

Paper studies the impact of the liquidity, underpricing and ownership up on both the short term and long term performance of the Initial Public Offer (IPO) stocks in the equity markets of India. Empirical analysis is undertaken to study the impact of liquidity, underpricing and ownership on Performance of IPO stocks. Multiple regression analysis is undertaken for analyzing the impact. It is fou...

متن کامل

Calibrating the calibrators.

Serial measures of lung function are essential for the long term monitoring of chronic diseases such as chronic obstructive pulmonary disease (COPD) and pulmonary fibrosis where the main aim is to limit disease progression. Measures of forced expiratory volume in one second (FEVI) and forced vital capacity (FVC) are generally the most reproducible and therefore suitable for long term disease mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thorax

دوره 51 10  شماره 

صفحات  -

تاریخ انتشار 1996