False selection of syringe-brand compatibility and the method of correction during target-controlled infusion of propofol

نویسندگان

  • Yun-Jeong Chae
  • Jong-Yeop Kim
  • Do-Won Kim
  • Bong-Ki Moon
  • Sang-Kee Min
چکیده

BACKGROUND We evaluated volumetric differences of syringe brand compatibilities, and investigated the impact of false brand settings on target-controlled infusion (TCI) and their methods of correction. METHODS Gravimetric measurement of 10 ml bolus infusions was performed using BD Plastipak (BDP) and Terumo compatible syringes, while setting to 7 different kinds of brand compatibilities (BDP, Sherwood Monoject, BD Perfusion, Braun Perfusor, Braun Omnifix, Fresenius Injectomat, and Terumo). To investigate the performance of TCI using BDP with a false setting to Terumo (BDPTERUMO) and Terumo to BDP (TERUMOBDP), 24 TCI targeting 4.0 µg/ml of effect-site concentration (Ceff) of propofol were performed. Subsequently, another 24 TCI were evaluated for simple corrections of false settings at 30 min. We also investigated 24 TCI using active corrections (fill-up for BDPTERUMO, evacuation for TERUMOBDP) based on the pharmacokinetics of propofol. The Ceff at 30 min of TCI and time to normalize to ± 5% of target concentration (T±5%target) were compared. RESULTS The Ceff of BDPTERUMO showed negative bias and 17.2% inaccuracy, and the Ceff of TERUMOBDP showed positive bias and 19.5% inaccuracy. The Ceff at 30 min showed no difference between the methods of correction in BDPTERUMO or TERUMOBDP. The T±5%target in both the active corrections was significantly shorter than that of each simple corrections (P < 0.001). CONCLUSIONS False brand setting of syringe proportionally maintained different predicted concentrations as much as the volumetric differences of syringe brand. Based on the results, it is proposed that correction methods based on pharmacokinetics could effectively normalize the differences, without giving up the wrong TCI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Target-controlled infusions of remifentanil and propofol during laparoscopic cholecystectomy

We have had this study to evaluate the clinical profile of target-controlled infusion-based anesthesia using remifentanil and propofol. 116 ASA I-II patients undergoing elective laparoscopic cholecystectomy (LCH) were enrolled. TCI Remifentanil was set at 8 micrograms. L - 1 as target and TCI propofol at 4 mcg/ml throughout the whole procedure. The hemodynamics during induction of anesthesia an...

متن کامل

Target-controlled infusions of remifentanil and propofol during laparoscopic cholecystectomy

We have had this study to evaluate the clinical profile of target-controlled infusion-based anesthesia using remifentanil and propofol. 116 ASA I-II patients undergoing elective laparoscopic cholecystectomy (LCH) were enrolled. TCI Remifentanil was set at 8 micrograms. L - 1 as target and TCI propofol at 4 mcg/ml throughout the whole procedure. The hemodynamics during induction of anesthesia an...

متن کامل

A Comparative Study of Remifentanil/Propofol versus Alfentanil/Propofol for Wake-up Test in Major Spinal Surgery

Background: Early warning of potential damage to spinal cord during major spinal surgery is highly desirable to prevent post-operative neurological deficits. Wake-up test is a simple, safe and reliable method of recognition of such a complication, and has been extensively used in many spinal surgical units. The present study is evaluating the remifentanil, propofol versus alfentanil, propofol a...

متن کامل

Correction of target-controlled infusion following wrong selection of emulsion concentrations of propofol

BACKGROUND We investigated the correction methods following wrong-settings of emulsion concentrations of propofol as a countermeasure against erroneous target-controlled infusions (TCI). METHODS TCIs were started with targeting 4.0 µg/ml of effect-site concentration (Ceff) of propofol, and the emulsion concentrations were selected for 2.0% instead of 1.0% (FALSE1-2, n = 24), or 1.0% instead o...

متن کامل

Smart syringe pumps for drug infusion during dental intravenous sedation

Dentists often sedate patients in order to reduce their dental phobia and stress during dental treatment. Sedatives are administered through various routes such as oral, inhalation, and intravenous routes. Intravenous administration has the advantage of rapid onset of action, predictable duration of action, and easy titration. Typically, midazolam, propofol or dexmedetomidine are used as intrav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 64  شماره 

صفحات  -

تاریخ انتشار 2013