Late complications of electrotherapy - a clinical analysis of indications for transvenous removal of endocardial leads: a single centre experience.

نویسندگان

  • Anna Polewczyk
  • Andrzej Kutarski
  • Andrzej Tomaszewski
  • Maciej Polewczyk
  • Marianna Janion
چکیده

BACKGROUND Despite advances in electrotherapy, late complications constitute an increasing clinical and therapeutic problem. Transvenous lead extraction (TLE) is becoming a safe and effective approach to the treatment of such complications. AIM To assess indications for TLE and to evaluate safety and efficacy of TLE procedures. METHODS A retrospective clinical analysis of 100 patients with complications of electrotherapy admitted to a tertiary care centre in 2008-2011. RESULTS In 2008-2011, the number of electrotherapy complications increased markedly. The most frequent reason for TLE was lead dysfunction (62% of patients, including 31% with an implanted cardioverter-defibrillator [ICD] and 31% with a pacemaker [PM]). The most common type of lead dysfunction was conductor damage (38% of patients, including 23% with ICD, 15% with PM), followed by late myocardial perforation (14% of patients, including 7% with ICD, 7% with PM), abnormal course of the lead (7% of patients, including 1% with ICD, 6% with PM), and lead insulation failure (3% of patients). Other reasons for TLE were infectious complications (24% of patients, including 15% with PM pocket infection), venous insufficiency (17% of patients, including 10% in whom an indwelling lead was a direct obstacle to switching the pacing mode), and the need to switch the pacing mode (4% of patients). Procedural efficacy was 96% (lead fragments were left in place in 4% of patients). No significant clinical complications were observed in any of the patients in the periprocedural period. CONCLUSIONS Clinical manifestations of electrotherapy complications in the study group varied and included a relatively small number of infectious complications (24%) and a relatively large number of late myocardial perforations (14%). Efficacy and safety of the procedures were very high.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous extraction of endocardial leads--a single centre experience in 120 patients.

BACKGROUND The expanding number of patients treated with pacing, especially resynchronisation therapy and pacing system upgrades as well as leads remaining inactive, and prolonged life expectancy are the causes of an increase of the number of electrodes in pacemaker patients. The growing problem with endocardial lead infections and excess leads has made percutaneous lead removal technology wide...

متن کامل

Complications of permanent cardiac pacing in patients with persistent left superior vena cava.

BACKGROUND Persistent left superior vena cava (PLSVC) is present in about 0.3-0.5% of the general population and in about 12% of patients with other abnormalities. This congenital anomaly is usually asymptomatic and does not cause any physiological problems. However, it may become a significant problem in multiple clinical situations. Various complications related to PLVSC are encountered in an...

متن کامل

Indications for Prophylactic Removal of Unerupted Asymptomatic Pathology-free Third Molars Referred by Iranian Orthodontists

Introduction: The management of asymptomatic impacted wisdom teeth remains a controversial issue. Although oral surgeons usually extract such teeth, but orthodontists often manage the condition. Because not only majority of orthodontic patients have asymptomatic impacted wisdom teeth but also some of them need to be extracted for orthodontic issues or to complete orthodontic therapy. This study...

متن کامل

One-Year Follow-Up of Patients Undergoing Transvenous Extraction of Pacemaker and Defibrillator Leads

INTRODUCTION The number of pacemaker and ICD implantations has increased substantially in the recent years. Therefore, complications are also observed in a greater number. In many cases, transvenous extraction of the previously implanted device (pacemaker or ICD) is the only solution. One may find in the literature information about the efficacy and safety of that procedure, but data concerning...

متن کامل

Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

BACKGROUND Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. METHODS Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Kardiologia polska

دوره 71 4  شماره 

صفحات  -

تاریخ انتشار 2013