Monitoring of electrical current in rabbit and porcine cartilage tissue during electromechanical reshaping
نویسندگان
چکیده
Electro Mechanical Reshaping (EMR) with platinum needle electrodes has been recently developed to shape cartilage without conventional cut and suture surgery. This study investigates the relationship between the voltage applied, the electrical current measured during EMR with platinum needles, and the resulting shape. Monitoring the electrical current provides information to model the electro-chemistry, which will aid in determining the onset of shape stabilization. Rabbit septal, rabbit auricular, porcine auricular, and porcine costal grafts were bent into a 90° angle using a moulage. Platinum needle electrodes were then placed in contact with the cartilage and a constant voltage was applied for a set time. The electrical current was measured during the process and total charge transferred was calculated. The cartilage specimen was then removed from the jig and photographed after one minute in order to determine the resulting bend angle. Results show that a higher current in tissue is produced with increasing applied voltage. Each current trace is unique and is dependent on tissue thickness and inter-electrode distances. Understanding the electrical current process ultimately leads to optimizing EMR and feedback control. Voltage, for example, could be varied in real-time during EMR to produce a constant chemical reaction rate and potentially reduce total tissue dehydration in contact with electrodes. In conclusion, electric current traces provide information about chemical kinetics during EMR that depend on exposure settings, and monitoring these traces is an important step in optimizing the reshaping process. Published: 29 October 2010
منابع مشابه
Using optical coherence tomography to monitor effects of electromechanical reshaping in septal cartilage
Electromechanical reshaping (EMR) of cartilage is a promising noninvasive technique with potential for broad application in reconstructive surgery. EMR involves applying direct current electrical fields to localized stress regions and then initiating a series of oxidation-reduction reactions, thus effecting a shape change. Previous EMR studies have focused on macroscopic structural measurements...
متن کاملElectromechanical reshaping of septal cartilage.
OBJECTIVES This study describes the process of tissue electroforming and how shape changes in cartilage can be produced by the application of direct current (DC). The dependence of shape change on voltage and application time is explored. STUDY DESIGN Basic investigation using ex vivo porcine septal cartilage grafts and electromechanical cartilage deformation focused on development of a new s...
متن کاملThe Effect of pH on Rabbit Septal Cartilage Shape Change: Exploring the Mechanism of Electromechanical Tissue Reshaping
INTRODUCTION Electromechanical reshaping (EMR) involves the application of an electrical current to mechanically deformed cartilage to create sustained tissue shape change. Although EMR may evolve to become an inexpensive and reliable way of producing shape change in cartilage during reconstructive surgery, the precise mechanism of EMR is unknown. We aim to examine the isolated effect of proton...
متن کاملMonitoring of Biological Changes in Electromechanical Reshaping of Cartilage Using Imaging Modalities
Electromechanical reshaping (EMR) is a promising surgical technique used to reshape cartilage by direct current and mechanical deformation. It causes local stress relaxation and permanent alterations in the shape of cartilage. The major advantages of EMR are its minimally invasive nature and nonthermal electrochemical mechanism of action. The purpose of this study is to validate that EMR does n...
متن کاملElectromechanical reshaping of ex vivo porcine trachea.
OBJECTIVES The trachea is a composite cartilaginous structure particularly prone to various forms of convexities. Electromechanical reshaping (EMR) is an emerging technique used to reshape cartilaginous tissues by applying electric current in tandem with imposed mechanical deformation to achieve shape change. In this study, EMR was used to reshape tracheal cartilage rings to demonstrate the fea...