Vicarious Calibration of Beijing-1 Multispectral Imagers
نویسندگان
چکیده
For on-orbit calibration of the Beijing-1 multispectral imagers (Beijing-1/MS), a field calibration campaign was performed at the Dunhuang calibration site during September and October of 2008. Based on the in situ data and images from Beijing-1 and Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), three vicarious calibration methods (i.e., reflectance-based, irradiance-based, and cross-calibration) were used to calculate the top-of-atmosphere (TOA) radiance of Beijing-1. An analysis was then performed to determine or identify systematic and accidental errors, and the overall uncertainty was assessed for each individual method. The findings show that the reflectance-based method has an uncertainty of more than 10% if the aerosol optical depth (AOD) exceeds 0.2. The cross-calibration method is able to reach an error level within 7% if the images are selected carefully. The final calibration coefficients were derived from the irradiance-based data for 6 September 2008, with an uncertainty estimated to be less than 5%.
منابع مشابه
Ground-look Radiometric Calibration Approaches for Remote Sensing Imagers in the Solar Reflective
Since the early 1990s, the availability of remote sensing imagery in the solar reflective (400 to 2500 nm) has seen a dramatic increase. Airborneand satellite-based sensors now cover this spectral range with a variety of spectral resolutions (from the multispectral to hyperspectral) and spatial resolutions ranging from better than 0.3 m for some airborne systems (and better than 1 m for satelli...
متن کاملHj-1a/b Multispectral Imagers Radiometric Stability in the First Year
On September 6th, 2008, HJ-1A/B, which is a Micro-satellite Constellation for Environment and Disaster Monitoring, was successfully launched in China. HJ-1A/B is composed by two small satellites named as Satellite-A (HJ-1A) and Satellite-B (HJ-1B). The payloads of HJ-1A include a multispectral imager and an interferometric imaging spectrometer; the payloads of HJ-1B include an infrared scanner ...
متن کاملVicarious Radiometric Calibration of a Multispectral Camera on Board an Unmanned Aerial System
Combinations of unmanned aerial platforms and multispectral sensors are considered low-cost tools for detailed spatial and temporal studies addressing spectral signatures, opening a broad range of applications in remote sensing. Thus, a key step in this process is knowledge of multi-spectral sensor calibration parameters in order to identify the physical variables collected by the sensor. This ...
متن کاملRadiometric Ground Truthing for Airborne and Satellite Sensor Tests
This paper presents processes and performance for ground-based measurements used by The Boeing Company and RESOURCE21 for vicarious calibration tests of airborne and satellite multispectral and hyperspectral sensors. We highlight our methodology for measuring downwelling irradiance and scene radiance and reflectance from 400 to 2500 nm, and describe in-house enhancements made to commercial spec...
متن کاملOptical Sensor
This paper is a review of the various methods. in use, or under development, to calibrate space-multispectral imaging systems in the solar-reflective range. We introduce the subject by distinguishing between absolute and relative calibration, briefly discussing the use of scene and sensor models, and describing five calibration desiderata. We then briefly describe the different types of existin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Remote Sensing
دوره 6 شماره
صفحات -
تاریخ انتشار 2014