Computer simulations concerning influence of target motion on dose distribution delivered by the GSI raster scanner

نویسندگان

  • Q. Li
  • S. Groezinger
  • T. Haberer
  • U. Weber
  • G. Kraft
چکیده

Target motion is a very big problem in conformal radiotherapy (CRT), especiallly for a charged particle beam because of its less lateral scattering and sharp Bragg peak. In the pilot project of the heavy-ion cancer therapy at GSI, patients with head and neck tumors are treated with a magnetic raster scanner[1]. However, if the raster scanner is used to treat patients with body tumors, motion of tumors is present in the lung, breast, liver, kidney and other disease sites, e.g. due to respiration. Therefore, applying the static dose optimization schemes[2] to the moving target by the advanced beam scanning technique could lead to a inhomogeneous dose distribution. So computer simulations about target motion were performed and Gaussian beam profile and sinusoidal movement are assumed as follows,

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study

Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

متن کامل

Experimental validation of survival calculations in the presence of motion

The software TRiP98 [1] is successfully used at GSI for treatment planning of stationary tumors. It is capable to calculate the absorbed dose and the biologically effective dose resulting from the superposition of usually several thousand C-12 pencil beams. Treatment is delivered with the raster scanner system [2]. If the target is subject to respiratory motion, treatment is not yet possible be...

متن کامل

The influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study

Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...

متن کامل

Volume Conformal Irradiation of Moving Target Volumes with Scanned Ion Beams

The intensity modulated raster scanning technique enables an extremely precise irradiation of tumours, which can be fixed in position and do not move. This thesis investigates how to extend raster scanning to moving target volumes, like in the thorax. Two different strategies were studied: A rescanning of the volume which is not correlated to the target motion and an active realignment of the b...

متن کامل

Verification of Complex 3D-Dose Distributions in Carbon Ion Irradiation

In radiotherapy with swift carbon ions very complex dose distributions are applied to a desired target volume. Up to now at the GSI radiotherapy project only regide target volumes in the skull of patients are treated. Extending the benefit of carbon ion radiotherapy to the whole patients body, problems of target motion as heart beat or breathing will occur. Using raster scan technique this moti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001