Gastric emptying and motility: assessment with MR imaging--preliminary observations.
نویسندگان
چکیده
PURPOSE To evaluate a magnetic resonance (MR) imaging method for simultaneous assessment of gastric emptying and motility. MATERIALS AND METHODS Gastric emptying and motility were measured in nine volunteers after ingestion of a liquid meal. A specially designed MR imaging protocol was used that allowed simultaneous assessment of gastric emptying (spatial resolution, 1.5 mm; corrected for gastric secretion volume) and gastric motility (temporal resolution, 1.2 seconds; spatial resolution, 3.1 mm). To evaluate the ability to detect small changes in gastric motor activity with findings from this method, the influence of a prokinetic agent (loxiglumide) on gastric emptying and motility was tested in five volunteers. RESULTS Each contraction could be individually visualized at MR imaging. Administration of loxiglumide resulted in decreased gastric half-emptying time (mean +/- 1 standard error of the mean, 88.1 minutes +/- 6.3 for the placebo and 39.1 minutes +/- 6.7 for loxiglumide) and increased gastric motility (contraction frequency, 2.26 contractions per minute +/- 0.15 for the placebo and 3.04 per minute +/- 0.04 for loxiglumide). CONCLUSION MR imaging makes it feasible to study gastric emptying and gastric motility and to determine the influence of drugs on gastric motor activity.
منابع مشابه
Monitoring Gastric Filling, Satiety and Gastric Emptying in a Patient with Gastric Balloon Using Functional Magnetic Resonance Imaging—A Feasibility Report
BACKGROUND Intragastric balloons are used for short term weight loss therapy in obese. It is possible to monitor the ballon with sonography, however this method is sometimes insufficient in obese patients. Therefore MRI seems to be a potential therapy-monitoring option. PURPOSE In this feasibility report we want to demonstrate the potential use of functional MRI in monitoring gastric filling,...
متن کاملGastric accommodation and motility are influenced by the barostat device: Assessment with magnetic resonance imaging.
The barostat is considered the gold standard for evaluation of proximal gastric motility especially for the accommodation response to a meal. The procedure is invasive because it involves the introduction of an intragastric catheter and bag and is not always well tolerated. Moreover, the barostat bag itself may influence motility. Nowadays magnetic resonance imaging (MRI) is able to measure sev...
متن کاملCharacterization of gastric volume responses and liquid emptying in functional dyspepsia and health by MRI or barostat and simultaneous C-acetate breath test.
The assessment of gastric accommodation and emptying by different methodologies provides inconsistent results. We aimed to compare magnetic resonance imaging (MRI), barostat and 13C-acetate breath test (BT) for the assessment of gastric volume responses and emptying in healthy controls (HC) and patients with functional dyspepsia (FD). Eight HC and eight FD patients underwent: (i) continuous BT ...
متن کاملValidation of Ultrasonography for Assessment of Gastric Emptying Time in Healthy Cats by Radionuclide Scintigraphy
BACKGROUND The prevalence of gastric emptying (GE) disorders in cats is unknown due to lack of clinically applicable diagnostic tests. OBJECTIVES The principal aim of this study was to assess correlation between scintigraphic and ultrasonographic measurements of GE time (GET) in healthy cats. Additionally, variability of ultrasonographic GET, and correlation between scintigraphy and ultrasono...
متن کاملA technical review and clinical assessment of the wireless motility capsule.
The wireless motility/pH capsule (WMC) is an orally ingested, nondigestible, data recording device that enables the simultaneous assessment of regional and whole gut transit. Approved by the US Food and Drug Administration for the evaluation of patients with suspected delayed gastric emptying and the evaluation of colonic transit time in patients with chronic idiopathic constipation, this capsu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 207 1 شماره
صفحات -
تاریخ انتشار 1998