Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography.

نویسندگان

  • Arnold C T Ng
  • Victoria Delgado
  • Frank van der Kley
  • Miriam Shanks
  • Nico R L van de Veire
  • Matteo Bertini
  • Gaetano Nucifora
  • Rutger J van Bommel
  • Laurens F Tops
  • Arend de Weger
  • Giuseppe Tavilla
  • Albert de Roos
  • Lucia J Kroft
  • Dominic Y Leung
  • Joanne Schuijf
  • Martin J Schalij
  • Jeroen J Bax
چکیده

BACKGROUND 3D transesophageal echocardiography (TEE) may provide more accurate aortic annular and left ventricular outflow tract (LVOT) dimensions and geometries compared with 2D TEE. We assessed agreements between 2D and 3D TEE measurements with multislice computed tomography (MSCT) and changes in annular/LVOT areas and geometries after transcatheter aortic valve implantations (TAVI). METHODS AND RESULTS Two-dimensional circular (pixr(2)), 3D circular, and 3D planimetered annular and LVOT areas by TEE were compared with "gold standard" MSCT planimetered areas before TAVI. Mean MSCT planimetered annular area was 4.65+/-0.82 cm(2) before TAVI. Annular areas were underestimated by 2D TEE circular (3.89+/-0.74 cm(2), P<0.001), 3D TEE circular (4.06+/-0.79 cm(2), P<0.001), and 3D TEE planimetered annular areas (4.22+/-0.77 cm(2), P<0.001). Mean MSCT planimetered LVOT area was 4.61+/-1.20 cm(2) before TAVI. LVOT areas were underestimated by 2D TEE circular (3.41+/-0.89 cm(2), P<0.001), 3D TEE circular (3.89+/-0.94 cm(2), P<0.001), and 3D TEE planimetered LVOT areas (4.31+/-1.15 cm(2), P<0.001). Three-dimensional TEE planimetered annular and LVOT areas had the best agreement with respective MSCT planimetered areas. After TAVI, MSCT planimetered (4.65+/-0.82 versus 4.20+/-0.46 cm(2), P<0.001) and 3D TEE planimetered (4.22+/-0.77 versus 3.62+/-0.43 cm(2), P<0.001) annular areas decreased, whereas MSCT planimetered (4.61+/-1.20 versus 4.84+/-1.17 cm(2), P=0.002) and 3D TEE planimetered (4.31+/-1.15 versus 4.55+/-1.21 cm(2), P<0.001) LVOT areas increased. Aortic annulus and LVOT became less elliptical after TAVI. CONCLUSIONS Before TAVI, 2D and 3D TEE aortic annular/LVOT circular geometric assumption underestimated the respective MSCT planimetered areas. After TAVI, 3D TEE and MSCT planimetered annular areas decreased as it assumes the internal dimensions of the prosthetic valve. However, planimetered LVOT areas increased due to a more circular geometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.

can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...

متن کامل

Assessment of the aortic root using real-time 3D transesophageal echocardiography.

BACKGROUND Precise evaluation of the aortic root geometry prior to transcatheter aortic valve implantation is important for procedural success in patients with aortic stenosis (AS). To determine the potential for 3-dimensional transesophageal echocardiography (3DTEE), the aims of the present study were: (1) to assess the accuracy of 3DTEE measurements of the aortic root using multidetector comp...

متن کامل

A Framework for the Systematic Characterization of the Aortic Valve Complex by Real-Time Three Dimensional Echocardiography: Implications for Transcatheter Aortic Valve Replacement

Transcatheter aortic valve replacement (TAVR) has become a viable alternative to surgical aortic valve replacement in both high-risk and inoperable patients with symptomatic severe aortic stenosis [1]. A successful TAVR procedure is heavily dependent on appropriate patient selection and detailed morphologic characterization of the aortic valve complex to prevent device migration, coronary arter...

متن کامل

Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

INTRODUCTION Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. AIM We want to share our experience with transcatheter aor...

متن کامل

Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root.

BACKGROUND To retrospectively investigate the potential cause of contained rupture of the aortic root in balloon-expandable transcatheter aortic valve implantation (TAVI) by means of pre- and postinterventional multislice computed tomography. METHODS AND RESULTS Seventy-two patients (mean age 82±7 years, mean aortic valve area 0.69±0.19 cm(2)) underwent balloon-expandable TAVI using the Edwar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2010