Functional MR imaging of the awake monkey in a novel vertical large-bore 7 Tesla setup

نویسندگان

  • J. Pfeuffer
  • J. Pauls
  • M. Augath
  • T. Steudel
  • H. Merkle
  • N. K. Logothetis
چکیده

J. Pfeuffer, J. Pauls, M. Augath, T. Steudel, H. Merkle, N. K. Logothetis Max Planck Institute for biological Cybernetics, Tuebingen, D, Germany, LFMI, NIH/NINDS, Bethesda, MD, United States First fMRI results in the awake trained monkey (Macaca mulatta) using a novel vertical 7T/60cm MR system are reported. The setup was custom-designed for MR imaging of monkeys in upright position and simultaneous electrophysiological recording. Using fast gradients and optimized RF coils, the benefits of high magnetic field with increased signal and contrast-to-noise ratio are demonstrated in high-resolution anatomical and functional images. Introduction Functional MR imaging in monkeys promises to build a bridge between brain research in humans and the large body of systems neuroscience work in animals [1]. Simultaneous fMRI and electrophysiology was recently used in the anesthetized monkey to elucidate the neural activity underlying the fMRI BOLD signal [2,3]. Here we present the first results from a novel high field (7T), largebore (60cm) vertical MR system, in which MR imaging and electrophysiology is performed in the awake trained monkey. Upright positioning of the animal was chosen for fMRI to minimize discomfort, expedite their training process, and ensure longer cooperation during the demanding psychophysical testing. MR System and Setup The 7 Tesla magnet has a 60 cm bore, an overall height of 6.40 m, and an empty weight of 80 tons. The system, extending over three floors, is quality shielded for low and high-frequencies to ensure noise-free electrophysiological recording of both local field and action potentials inside or outside the magnet bore. It is controlled by a four-channel BRUKER BioSpec console. The 38-cm gradient insert achieves 80 mT/m in 130 μs. A variety of surface coils, quadrature surface coils, saddle coils, actively-decoupled combination coils, and surface coil assemblies for hetero-nuclear studies were custom-built similar to designs reported previously [4-6]. A prototype of primate chair was custom-designed and built to accommodate for the positioning of the electrophysiology assortments, the reward of the animal, the stimulus presentation, and the control of unwanted movement. The chair is driven into the magnet with a vertical transport system. All cables connecting the proximal end of the recording and monitoring devices to the main equipment were fed through a filter panel at the lower end of the chair. A similar chair was built for the experiments on anaesthetized animals. Full-field visual stimulation was done with a rotating checkerboard using 4s stim-on, 8s stim-off in 8 epochs. For fMRI experiments in the awake monkey, severe challenges like motion and dynamic off-resonance due to breathing, chewing, or body movement needed to be tackled. Results Initial MR imaging experiments were performed with gradient echo, spin echo, and inversion-recovery sequences to determine T1, T2, and T2* values for tissue. As expected, T2 of gray matter was decreased to 50 ms at 7 T compared to about 70 ms at 4.7T [1]. Functional imaging on the awake monkey was performed using single-shot GE-EPI with 0.75x0.75 mm resolution (1 mm slice thickness, TE 25 ms, TR 0.5 s for 7 slices). Results from a single fMRI series are shown in Fig. 1 and 2 demonstrating robust activation with high cc values >0.5 and BOLD percent changes >5%. The quality of the first anatomical and functional images acquired with this system promises the ultra-high resolution required to examine the local electrophysiological signal measured with microelectrodes in the context of the activation of small networks assessed in functional MR imaging. References 1-4. Logothetis NK et al. [2002] Phil Trans R Soc Lond B 357:1003; [1999] Nature Neurosci 2(6):555-62; [2001] Nature 412:150-57; [2002] Neuron 35:227-42. 5-6. Merkle H et al. [1999] MAGMA 8 S1,532; [2002] MAGMA 15 S1,425.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical and functional MR imaging in the macaque monkey using a vertical large-bore 7 Tesla setup.

Functional magnetic resonance imaging (MRI) in the nonhuman primate promises to provide a much desired link between brain research in humans and the large body of systems neuroscience work in animals. We present here a novel high field, large-bore, vertical MR system (7 T/60 cm, 300 MHz), which was optimized for neuroscientific research in macaque monkeys. A strong magnetic field was applied to...

متن کامل

Proton MR Spectroscopy at 7 Tesla in the Macaque monkey

J. Pfeuffer, C. Juchem, H. Merkle, N. K. Logothetis Max Planck Institute for biological Cybernetics, Tuebingen, D, Germany, LFMI, NIH/NINDS, Bethesda, MD, United States First MR spectroscopy results in the anaesthetized and the awake trained monkey (Macaca mulatta) are reported using a novel vertical bore 7T/60cm MR system. The setup was custom-designed for MR imaging and spectroscopy of monkey...

متن کامل

Perfusion-based high-resolution fMRI in the primate brain using a novel vertical large-bore 7 Tesla setup

Introduction Functional MR imaging in monkeys promises a bridge between brain research in humans and the large body of systems neuroscience work in animals. Prerequisite for successful interspecies-comparisons, however, is a profound understanding of the neural events underlying the hemodynamic responses. Combined physiology and neuroimaging experiments made the first step in this direction by ...

متن کامل

A novel coil array for combined TMS/fMRI experiments at 3 T.

PURPOSE To overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla. METHODS The state-of-the-art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitiv...

متن کامل

Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

Echo-planar imaging (EPI) sequences were developed for a 9.4 Tesla vertical standard bore (~54 mm) superconducting magnet using an unshielded gradient coil optimized for live mice imaging and a data correction technique with reference scans. Because EPI requires fast switching of intense magnetic field gradients, eddy currents were induced in the surrounding metallic materials, e.g., the room t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002