Measurement of the refractive index of highly turbid media.
نویسندگان
چکیده
We demonstrate a first simultaneous measurement of the real and imaginary parts of the refractive index of a highly turbid medium by observing the real-time reflectance profile of a divergent laser beam made incident on the surface of the turbid medium. We find that the reflectance data are well described by Fresnel theory that correctly includes the effect on total internal reflection of angle-dependent penetration into the turbid medium.
منابع مشابه
Refractive index tomography of turbid media by bifocal optical coherence refractometry.
We demonstrate tomographic imaging of the refractive index of turbid media using bifocal optical coherence refractometry (BOCR). The technique, which is a variant of optical coherence tomography, is based on the measurement of the optical pathlength difference between two foci simultaneously present in a medium of interest. We describe a new method to axially shift the bifocal optical pathlengt...
متن کاملThe photon transport equation for turbid biological media with spatially varying isotropic refractive index.
Using the principle of energy conservation and laws of geometrical optics, we derive the photon transport equation for turbid biological media with spatially varying isotropic refractive index. We show that when the refractive index is constant, our result reduces to the standard radiative transfer equation and when the medium is lossless and free of scattering to the well known geometrical opt...
متن کاملMeasurement of the refractive index of highly turbid media: reply to comment.
Peiponen et al. [Opt. Lett.35, 4108 (2010)] have expressed concern that a theoretical model we proposed in Calhoun et al. [Opt. Lett.35, 1224 (2010)] for total internal reflection from a turbid medium may be inconsistent with the experimental data, in the sense that the model fails to take into account unexplained oscillations in our data. We show that their concern arises from misinterpretatio...
متن کاملMeasurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry
In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...
متن کاملInternal refractive index changes affect light transport in tissue
This investigation explores the effect of index of refraction, as an optical property, on light transport through optically turbid media. We describe a model of light propagation that incorporates the influence of refractive index mismatch at boundaries within a domain. We measure light transmission through turbid cylindrical phantoms with different distributions of refractive index. These dist...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics letters
دوره 35 8 شماره
صفحات -
تاریخ انتشار 2010