Measures of Impact Under Cascading Failure of Power Grid
نویسندگان
چکیده
A centrality measure has been proposed considering the directionality of power flow of future smart grid. Applicability of the proposed method has been evaluated in several standard IEEE test systems. Various comparisons are shown between impacts of removal of critical nodes found from two different models: nondirectional and bidirectional. Larger impact of removing critical nodes found from bidirectional flow model shows the utility of the proposed method. Measures of impacts considered are changes in path length, loss of connectivity and load lost during cascade.
منابع مشابه
Evaluating the potential of cascading failure occurrence due to line outage in power systems by information theory method and radial base functions
In power systems, a connected topology is created to increase reliability and economic performance. Increasing dimensions of power systems on the one hand and the need to continuously monitor power systems for secure operation on the other challenge the evaluation of power system security. In such conditions, due to economic conditions and considering the fast growth of consumers in a power sys...
متن کاملThe Impact of the Topology on Cascading Failures in Electric Power Grids
Cascading failures are one of the main reasons for blackouts in power transmission grids. The topology of a power grid, together with its operative state determine, for the most part, the robustness of the power grid against cascading failures. Secure electrical power supply requires, together with careful operation, a robust design of the electrical power grid topology. This paper investigates...
متن کاملAnalysis of Failures in the Power Grid via the Pseudo-inverse of the Admittance Matrix
Recent large-scale power outages demonstrated the limitations of percolationand epidemic-based tools in modeling failures in power grids. Hence, we study the impact of line failures on the flow changes and cascade in the transmission system of the power grid by using a linearized power flow model. We use the pseudo-inverse of the power grid admittance matrix to obtain upper bounds on the flow c...
متن کاملThe Impact of the Topology on Cascading Failures in a Power Grid Model
Cascading failures are one of the main reasons for large scale blackouts in power transmission grids. Secure electrical power supply requires, together with careful operation, a robust design of the electrical power grid topology. Currently, the impact of the topology on grid robustness is mainly assessed by purely topological approaches, that fail to capture the essence of electric power flow....
متن کاملCascading Failures: Survival versus Prevention
While measures can be taken to reduce the number of large-scale power losses due to failures of the generation and high-voltage transmission grid, such failures cannot be eliminated. The survival of essential missions is a more tractable problem than the prevention of all large cascading failures, and its solutions are verifiable. Thus, serious attention should be directed towards assuring the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -