Combination of Compressed Sensing and Parallel Imaging with Respiratory Motion Correction for Highly-Accelerated First- Pass Cardiac Perfusion MRI

نویسندگان

  • R. Otazo
  • D. Kim
  • D. K. Sodickson
چکیده

INTRODUCTION: First-pass cardiac perfusion MRI requires fast data acquisition to achieve an appropriate combination of temporal resolution, spatial resolution and spatial coverage for clinical studies [1]. We have recently presented a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE) to highly accelerate perfusion studies by jointly exploiting sparsity in the combined spatial (y) and temporal-frequency (f) domain and coil sensitivity encoding [2]. However, this method is sensitive to respiratory motion, which decreases sparsity in the y-f domain and produces temporal blurring in the reconstructed images. In this work, we present a rigid respiratory motion correction method to pre-register all the frames prior to combined compressed sensing and parallel imaging reconstruction (see Fig. 1). METHODS: First-pass cardiac perfusion MRI with 0.1 mmol/kg of Gd-DTPA (Magnevist) was performed using a modified multi-slice TurboFLASH pulse sequence. Two healthy volunteers were imaged on a whole-body 3T scanner (Siemens; Tim-Trio), using the standard 12-element body matrix coil array. Two examples were selected to demonstrate feasibility of the technique: (a) free-breathing scan and (b) breath-holding scan where the subject failed to hold his breath. The relevant imaging parameters include: FOV = 320x320 mm, image resolution = 1.7x1.7 mm, slicethickness = 8mm, TE/TR = 1.3/2.5 ms, repetitions = 40. An acceleration factor of 8 was used to acquire 10 slices per heartbeat with temporal resolution of 60ms/slice. Data undersampling was performed using a pseudorandom ky-t pattern to produce the incoherent artifacts required by compressed sensing [2]. Fully-sampled low-resolution coil sensitivity reference data were acquired in the first heartbeat. Image reconstruction was performed according to the flowchart shown in Fig. 1, using the k-t SPARSE-SENSE algorithm [2] with temporal FFT as sparsifying transform. First, an intermediate k-t SPARSE-SENSE reconstruction is generated for respiratory motion correction. Rigid motion between frames is detected by computing the displacement of the heart in each frame from this intermediate k-t SPARSE-SENSE reconstruction with respect to the reconstruction of the fully-sampled coil sensitivity reference data, using a crosscorrelation approach in the image domain [3]. The displacement was detected in a ROI covering the entire heart. Second, motion correction is performed by aligning all the frames in the accelerated data. The final k-t SPARSE-SENSE reconstruction is computed using the registered accelerated data. RESULTS: Rigid respiratory motion correction significantly increased sparsity in the combined spatial (y) and temporal-frequency (f) domain, which is due to better alignment among frames (Fig. 2). Fig. 3 shows k-t SPARSE-SENSE reconstruction of a representative slice from the freebreathing perfusion scan without and with motion correction. The utilization of motion correction decreased temporal blurring and produced images with higher sharpness. Fig. 4 shows k-t SPARSE-SENSE reconstruction of a representative slice from a partially breath-held scan. The reconstruction without motion correction presented significant artifacts for time frames where the subject failed to hold his breath, due to temporal blurring. These artifacts were highly reduced by the reconstruction with motion correction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combination of compressed sensing and parallel imaging with respiratory motion correction for highly-accelerated cardiac perfusion MRI

Introduction Cardiac perfusion MRI requires fast data acquisition to achieve an appropriate combination of temporal resolution, spatial resolution and spatial coverage for clinical studies [1]. We have recently presented a combination of compressed sensing and parallel imaging (k-t SPARSESENSE) to highly accelerate perfusion studies [2]. However, this method is sensitive to respiratory motion, ...

متن کامل

Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

First-pass cardiac perfusion MRI is a natural candidate for compressed sensing acceleration since its representation in the combined temporal Fourier and spatial domain is sparse and the required incoherence can be effectively accomplished by k-t random undersampling. However, the required number of samples in practice (three to five times the number of sparse coefficients) limits the accelerat...

متن کامل

Highly-Accelerated First-Pass Cardiac Perfusion MRI Using Compressed Sensing and Parallel Imaging

INTRODUCTION: First-pass cardiac perfusion MRI is a promising modality for the assessment of coronary artery disease. Recently developed dynamic parallel imaging techniques, such as k-t SENSE [1] and k-t GRAPPA [2], can be used to perform up to 10-fold accelerated perfusion imaging by exploiting the difference in coil sensitivities and spatio-temporal correlations. Such techniques can be used t...

متن کامل

Motion-corrected compressed-sensing enables robust spiral first-pass perfusion imaging with whole heart coverage

Background First-pass perfusion imaging using CMR is an important tool for diagnosing coronary artery disease (CAD), but most clinical techniques are limited in their spatial coverage. While compressed-sensing (CS) holds promise for highly accelerated perfusion spiral imaging, CS techniques suffer from blurring artifacts in the setting of respiratory motion. Spiral pulse sequences have multiple...

متن کامل

Combination of Compressed Sensing, Parallel Imaging and Partial Fourier for Highly-Accelerated 3D First-Pass Cardiac Perfusion MRI

Introduction: First-pass myocardial perfusion MRI is a promising and noninvasive technique for evaluation of ischemic heart disease. 3D whole-heart coverage per heartbeat is desirable for clinical perfusion studies to overcome the contrast-to-noise ratio (CNR) and volumetric coverage limitations associated with multi-slice 2D perfusion MRI studies [1-2]. Highly accelerated imaging is a necessar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010