Pneumatic Pressure Cell with Twin Diaphragms Embedding Spherical Corrugations in a Dual Diaphragm Structure
نویسندگان
چکیده
Thin metallic shallow spherical diaphragms are being used for measuring pneumatic pressure in process industries. The drift in vertex realized due to application of pressure is transformed into electrical signal and this is calibrated for pressure. We now propose a modified structure for the pressure cell by having double ended shallow spherical shells embedded with spherical corrugations as to enhance the sensitivity to a greater extent. By having dual such installation in the structure of the pressure cell it concedes further increase in sensitivity. The construction details of the diaphragm structure, theory and analysis to assess the performance are presented.
منابع مشابه
Vibrating Cantilever Transducer Incorporated in Dual Diaphragms Structure for Sensing Differential Pneumatic Pressure
Pneumatic pressure cells with thin metallic spherical diaphragm of shallow spherical shell configuration linked with vibrating wire pickup or vibrating cantilever pickup were reported in the past. In order to enhance the sensitivity of the pressure cell this work considers dual diaphragm structure fitted with cantilever pickup. The design and development of the pressure cell with this dual diap...
متن کاملLaterally Driven Resonant Pressure Sensor with Etched Silicon Dual Diaphragms and Combined Beams
A novel structure of the resonant pressure sensor is presented in this paper, which tactfully employs intercoupling between dual pressure-sensing diaphragms and a laterally driven resonant strain gauge. After the resonant pressure sensor principle is introduced, the coupling mechanism of the diaphragms and resonator is analyzed and the frequency equation of the resonator based on the triangle g...
متن کاملInvestigation of the Rigidity of Floor Diaphragms on the Behavior of Concrete Tall Buildings with Staggered Shear Walls under Lateral Loading
In most cases, structural engineers assume a concrete floor to be a rigid diaphragm. Although this simplification is in most cases acceptable, it should be noted that such an assumption may be distrusted due to certain problems. Concrete structures with staggered shear walls are among those whose analysis should be conducted with special concern for the behavior of their floor diaphragms. Howev...
متن کاملInvestigation of the Rigidity of Floor Diaphragms on the Behavior of Concrete Tall Buildings with Staggered Shear Walls under Lateral Loading
In most cases, structural engineers assume a concrete floor to be a rigid diaphragm. Although this simplification is in most cases acceptable, it should be noted that such an assumption may be distrusted due to certain problems. Concrete structures with staggered shear walls are among those whose analysis should be conducted with special concern for the behavior of their floor diaphragms. Howev...
متن کاملMultiple PV1 dimers reside in the same stomatal or fenestral diaphragm.
Several of the endothelium-specific structures that have been involved in microvascular permeability [such as caveolae, transendothelial channels (TECs), vesiculovacuolar organelles (VVOs), and fenestrae] can be provided with either a stomatal or fenestral diaphragm. In the case of fenestrae, the diaphragm has the presumed function of creating a permselective barrier for solutes from blood plas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CoRR
دوره abs/1203.2508 شماره
صفحات -
تاریخ انتشار 2011