Transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience

نویسندگان

  • Uğur Kocabaş
  • Hamza Duygu
  • Nihan Kahya Eren
  • Zehra İlke Akyıldız
  • Serhan Özyıldırım
  • Selcen Yakar Tülüce
  • Tuncay Kırış
  • Cem Nazlı
چکیده

OBJECTIVE In recent years there has been an increase in clinical situations requiring lead extraction procedures of implanted cardiac devices. In our clinic, extraction procedures are performed with Evolution® mechanical lead extraction system. In this manuscript we aimed to evaluate our lead extraction procedures. METHODS We retrospectively evaluated lead extraction procedures carried out on 41 patients [30 male, 11 female patient; mean age 61.5 ± 18.5 median 67 (23-85)] between 2008 and 2015 using Evolution® system. Procedural success, major and minor complications are determined according to previously published guidelines. RESULTS Mean duration of the lead implantation was 88.4 ± 62.5 months (6-240). Implanted device was a pacemaker in 27 (65.8 %) and ICD in 14 (34.2 %) of patients. Total 67 leads were extracted from the patients, 22 (32.8 %) were atrial, 30 (44.2 %) were ventricular, 14 (21.5 %) were dual coil defibrillator and 1 (1.5 %) was coronary sinus lead. Indications for lead removal were pacemaker decubitis and infection in 29 (70.8 %), lead dysfunction in 11 (26.8 %) and subclavian vein thrombosis in 1 (2.4 %) patient. Success rate with Evolution® system without using snare was 85.3 %. Clinical success rate was 97.5 % procedural success rate was 95.1 % and failure occured in one patient. Major complications occured in 2 (4.8 %) patients, 1 (2.4 %) was procedure related mortality. Minor complications were seen in 5 (12.2 %) of patients. CONCLUSIONS In our single center study it is shown that extraction of pacemaker and defibrillator leads of relatively long implantation duration and in an older age patient group may be successfully carried out using the Evolution® system. However due to potentially serious complications it is adviced to be done by experienced operators in centers with cardiovascular surgery backup.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath.

With the increasing number of implanted pacemakers and implantable cardioverter defibrillators, removal is required more frequently. Presently described is the transvenous extraction of a 26-year-old Accufix atrial lead using a mechanical dilator sheath. A 50-year-old male patient was admitted to the clinic with a pacemaker pocket infection. The atrial lead was an Accufix Bipolar J-Atrial activ...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Initial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads.

BACKGROUND In a previous randomized trial, the 12F laser sheath removed pacing leads via the implant vein more successfully than traditional mechanical tools alone. Two larger sizes of laser sheath, the 14F and 16F models, were developed to extract defibrillator leads and large-diameter pacing leads implanted for the chronic. These devices use pulsed ultraviolet laser light to core though fibro...

متن کامل

Deaths and cardiovascular injuries due to device-assisted implantable cardioverter–defibrillator and pacemaker lead extraction

AIMS An estimated 10,000-15,000 pacemaker and implantable cardioverter-defibrillator (ICD) leads are extracted annually worldwide using specialized tools that disrupt encapsulating fibrous tissue. Additional information is needed regarding the safety of the devices that have been approved for lead extraction. The aim of this study was to determine whether complications due to device-assisted le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016