Performance evaluation of the COBAS/TaqMan HIV-1 v2.0 in HIV-1 positive patients with low viral load: a comparative study.

نویسندگان

  • Pierpaolo Paba
  • Lavinia Fabeni
  • Massimo Ciccozzi
  • Carlo Federico Perno
  • Marco Ciotti
چکیده

HIV-1 viral load determination is a crucial step for monitoring the efficacy of highly active antiretroviral therapy (HAART) and predicts disease progression. Real-time PCR based assays are available for monitoring the viral load. They differ in sensitivity, genomic target region and dynamic range. In this study, the performance of the Roche Cobas Taqman HIV-1 v2.0 was evaluated on plasma samples from HIV-1 positive patients in parallel with the Abbott RealTime HIV-1 assay in a routine diagnostic setting. Overall, there was a good agreement between the two assays. However, some samples detected by the Abbott RealTime HIV-1 assay but below the limit of quantitation of the assay were found negative result when tested with the Roche Cobas Taqman HIV-1 v2.0. It is conceivable that signal anomalies or background noise may affect the lower-end precision of the Abbott RealTime HIV-1 assay. Based on these results, it is concluded that it is not recommended to switch platform during longitudinal viral load monitoring of HIV-1 positive patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of the new Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 for quantification of human immunodeficiency virus type 1 RNA.

Despite FDA approval and CE marking of commercial tests, manufacturer-independent testing of the technical aspects of newly developed tests is important. To evaluate the analytical performance and explore the clinical applicability of the new Roche COBAS AmpliPrep COBAS TaqMan HIV-1 test, version 2.0 (CAP/CTM v2.0), platform comparison was performed with the Roche CAP/CTM test, version 2.0, the...

متن کامل

Performance Evaluation of the Bioneer AccuPower® HIV-1 Quantitative RT-PCR kit: Comparison with the Roche COBAS® AmpliPrep/COBAS TaqMan® HIV-1 Test Ver.2.0 for Quantification of HIV-1 Viral Load in Indonesia.

BACKGROUND Measurement of viral load in human immunodeficiency virus type 1 (HIV-1) infected patients is essential for the establishment of a therapeutic strategy. Several assays based on qPCR are available for the measurement of viral load; they differ in sample volume, technology applied, target gene, sensitivity and dynamic range. The Bioneer AccuPower® HIV-1 Quantitative RT-PCR is a novel c...

متن کامل

Performance of the Aptima® HIV-1 Quant Dx Assay on the Panther System

The Aptima® HIV-1 Quant Dx Assay is a fully automated assay on the Panther system. It is based on TranscriptionMediated Amplification and real time detection technologies. This assay is intended for monitoring HIV-1 viral load in plasma specimens and for the detection of HIV-1 in plasma and serum specimens. Nine-hundred and seventy nine specimens selected at random from routine testing at St Th...

متن کامل

No Evidence for Human Papillomavirus in Patients with HIV in Iran

Background: Human Papillomaviruses (HPVs) have anestablished role in the development of cervical cancer. However, the presence of underlying conditions such as HIV/AIDS is necessary for this to occur. This studyaimed to evaluate the prevalence of HPV DNA in plasma samples from HIV-positive patients in Tehran, Iran. Methods: Plasma specimens from 95 patients diagnosed with HIV infection from Te...

متن کامل

Evaluation of the NucliSens EasyQ v2.0 Assay in Comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in Quantification of C-Clade HIV-1 in Plasma

Human immunodeficiency virus type 1 (HIV-1) genetic diversity poses a challenge to reliable viral load monitoring. Discrepancies between different testing platforms have been observed, especially for non-clade-B virus. Therefore we compare, in antiretroviral therapy (ART)-naïve South African subjects predominantly infected with HIV-1 clade-C, three commercially available assays: the COBAS Ampli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of virological methods

دوره 173 2  شماره 

صفحات  -

تاریخ انتشار 2011