Monte Carlo Simulation of BGA Failure Distributions for Virtual Qualification

نویسندگان

  • John W. Evans
  • Jillian Y. Evans
  • Andrew Mawer
چکیده

Any approach to qualification of advanced technologies during product development must include an assessment of variation expected in product life over the life cycle. However, testing product design options in development, to approach an optimal design, is costly and time consuming. Hence, simulation of product life distributions for virtual qualification, can be a valuable tool to evaluate and qualify design options. This paper presents a physics of failure based approach to virtual qualification of advanced area array assemblies, against solder fatigue failure. The approach applies Monte Carlo Simulation to evaluate solder joint fatigue life distributions, given material property variations and manufacturing capabilities. Preliminary results using the simple Engelmaier Model as the basis of simulations are presented. Simulation results are compared to data accumulated from two test environments and two BGA product types. The results reveal some of the limitations of the Engelmaier Model as a basis for simulation. They also show the potential of this approach to virtual qualification for design and manufacturing capability assessment in development. INTRODUCTION Product qualification is intended to assure that a new design will meet the lifetime required for the application with minimal risk of failure. In addition, qualification is used to assure manufacturing processes produce minimal risk of early failure due to defects or inadequate process capability. We are forced to recognize in applying qualification, that materials properties and various geometric variables subject to manufacturing processes are random variables. These variations give rise to uncertainty in product life, as shown in Figure 1. Material Properties Manufacturing Capability Product Life + pdfm pdfg pdflife Figure 1 Materials property variation Qualification must assure the design and manufacturing capability produce adequate product life. The method of qualification must also recognize variations in materials properties and manufacturing capability produce uncertainty in product life. In conventional qualification, we therefore select a sample size and test the sample products under stress to failure or until some specified time period. We then examine the confidence we have in our design and manufacturing processes. Yet, many options in architecture may be selected to create a hierarchy of packaging for an electronic product. There are many materials options and potential manufacturing processes. In addition, new developments provide expanding options. Virtual qualification is therefore desirable as an alternative to testing all potential options. Virtual qualification implies that we evaluate a model of the product under stress. We can therefore evaluate and qualify many options in architecture for a product in rapid time, at lower cost. However, we must still fulfill the requirement of understanding the impact of variation as illustrated above, in Figure 1. Hence, Monte Carlo simulation becomes a valuable approach to developing a virtual qualification scheme. The following sections present an approach to simulation of life based upon input variation of materials properties and manufacturing capability. To illustrate this approach to virtual qualification, we apply the process to Ball Grid Array architectures and compare the results to qualification test data on actual product. Two test conditions and architectures are evaluated. As summarized in Table 1. Table 1. Qualification Conditions Test Facility BGA Package Style Actual Test Sample Size Cyclic Conditions Jet Propulsion Laboratory 313 PBGA 35 mm X 35mm 1.27 mm pitch Full Array 15x15mm die n=13 -30 to +100C tD @100 C = 20min tD @-30 C = 10 min Ramp time = 20 min Motorola Semiconductor Products 119 PBGA 14 mm X 22 mm 1.27 mm pitch Full Array 9 x 16 mm die n = 27 0 to +100C tD = 5 min Ramp time = 10 min VIRTUAL QUALIFICATION BY SIMULATION A method of virtual qualification is summarized in Figure 2. In this case, time to failure models representing the dominant failure mechanisms are embedded in a Monte Carlo simulation. Input variations representing manufacturing capability and material properties are modeled as triangular distributions. These estimates must be extracted from materials testing and manufacturing history. The process is exercised as follows: • The test or application conditions are determined. • A failure model is selected. • The input distributions are then sampled using a random number generator. • The life is calculated from the failure model. • The result is stored. • The input distributions are sampled again and calculation is repeated for a preset number of samples. • The results of the stored are analyzed by fitting the data to a distribution, which represents the life distribution of the failure mechanism. In the case of the BGA application, we initially have selected the well-known Engelmaier model to represent the failure mechanism of solder fatigue for these initial studies. Fig. 2. Virtual Qualification Process by Monte Carlo Simulation (Evans and Evans 1999). Select Failure Mechanism Model t f=f(g,m,p,e,d) Calculate tf from Failure Mechanism Model and Save Result P r o b a b i l i t y

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localization of electron virtual SSD in a Siemens-Primus linear accelerator: Comparison of measurements with Monte Carlo simulation

Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...

متن کامل

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

Numerical Simulations for Reliability Assessment of Lead-Free Solder Interconnections in BGA Packages

Aalto University, P.O. Box 11000, FI-00076 Aalto www.aalto.fi Author Jue Li Name of the doctoral dissertation Numerical Simulations for Reliability Assessment of Lead-Free Solder Interconnections in BGA Packages Publisher School of Electrical Engineering Unit Department of Electronics Series Aalto University publication series DOCTORAL DISSERTATIONS 48/2011 Field of research Electronics Product...

متن کامل

Monte Carlo Simulation to Compare Markovian and Neural Network Models for Reliability Assessment in Multiple AGV Manufacturing System

We compare two approaches for a Markovian model in flexible manufacturing systems (FMSs) using Monte Carlo simulation. The model which is a development of Fazlollahtabar and Saidi-Mehrabad (2013), considers two features of automated flexible manufacturing systems equipped with automated guided vehicle (AGV) namely, the reliability of machines and the reliability of AGVs in a multiple AGV jobsho...

متن کامل

Comparison dose distributions from gamma knife unit 4C with CT data and non-CT data options of beamnrc code

Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999