Optimization of Tagged MRI for Quantification of Liver Stiffness Using Computer Simulated Data

نویسندگان

  • Serena Monti
  • Giuseppe Palma
  • Monica Ragucci
  • Lorenzo Mannelli
  • Marcello Mancini
  • Anna Prinster
چکیده

The heartbeat has been proposed as an intrinsic source of motion that can be used in combination with tagged Magnetic Resonance Imaging (MRI) to measure displacements induced in the liver as an index of liver stiffness. Optimizing a tagged MRI acquisition protocol in terms of sensitivity to these displacements, which are in the order of pixel size, is necessary to develop the method as a quantification tool for staging fibrosis. We reproduced a study of cardiac-induced strain in the liver at 3T and simulated tagged MR images with different grid tag patterns to evaluate the performance of the Harmonic Phase (HARP) image analysis method and its dependence on the parameters of tag spacing and grid angle. The Partial Volume Effect (PVE), T1 relaxation, and different levels of noise were taken into account. Four displacement fields of increasing intensity were created and applied to the tagged MR images of the liver. These fields simulated the deformation at different liver stiffnesses. An Error Index (EI) was calculated to evaluate the estimation accuracy for various parameter values. In the absence of noise, the estimation accuracy of the displacement fields increased as tag spacings decreased. EIs for each of the four displacement fields were lower at 0° and the local minima of the EI were found to correspond to multiples of pixel size. The accuracy of the estimation decreased for increasing levels of added noise; as the level increased, the improved estimation caused by decreasing the tag spacing tended to zero. The optimal tag spacing turned out to be a compromise between the smallest tag period that is a multiple of the pixel size and is achievable in a real acquisition and the tag spacing that guarantees an accurate liver displacement measure in the presence of realistic levels of noise.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

TWO-STAGE METHOD FOR DAMAGE LOCALIZATION AND QUANTIFICATION IN HIGH-RISE SHEAR FRAMES BASED ON THE FIRST MODE SHAPE SLOPE

In this paper, a two-stage method for damage detection and estimation in tall shear frames is presented. This method is based on the first mode shape of a shear frame. We demonstrate that the first mode shape slope is very sensitive to the story stiffness. Thus, at the first stage, by using the grey system theory on the first mode shape slope, damage locations are identified in shear frames. Da...

متن کامل

SPIO-Annexin V, a potential probe for MRI detection of radiation induced apoptosis

Background: Finding a suitable method for rapid, accurate and reliable estimation of absorbed dose has high priority in management of the radiation exposed persons. Shortly after radiation exposure, apoptosis is a major detriment in proliferative tissues such as the hematopoietic system. Therefore, quantification of apoptosis in these tissues could be useful for rapid estimation of radiation ex...

متن کامل

REGION MERGING STRATEGY FOR BRAIN MRI SEGMENTATION USING DEMPSTER-SHAFER THEORY

Detection of brain tissues using magnetic resonance imaging (MRI) is an active and challenging research area in computational neuroscience. Brain MRI artifacts lead to an uncertainty in pixel values. Therefore, brain MRI segmentation is a complicated concern which is tackled by a novel data fusion approach. The proposed algorithm has two main steps. In the first step the brain MRI is divided to...

متن کامل

FDG-PET/MRI fused data sets for the detection of liver metastases in patients undergoing systemic anticancer treatment

Background: To retrospectively describe imaging characteristics of liver metastases on fused FDG-PET/ MRI data sets and to compare the diagnostic accuracy of MRI and fused FDG-PET/MRI data sets for the detection of liver metastases in patients undergoing systemic anticancer treatment. Materials and Methods: 43 oncological patients (mean age: 56+/- 11 years) were investigated by FDG-PET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014