Accuracy of flow measurement with phase contrast MRI in a stenotic phantom: where should flow be measured?
نویسندگان
چکیده
Methods Herein, a series of detailed experiments are reported for validation of MR measurements of steady and pulsatile flows with stereoscopic particle image velocimetry (SPIV) on three different stenotic models with 50%, 74%, and 87% area occlusions. Mean inlet Reynolds number was 190 for both steady and pulsatile cases, mimicking the flow of the human common iliac artery. Axial PC-MRI images were acquired at three sites: inlet (two diameters proximal to the stenosis), throat, and outlet (two diameters distal to the stenosis) using a 3T TX Achieva Philips MRI scanner with slice thickness = 4 mm, resolution = 1 × 1 mm, TE/TR = 3.0/4.0 ms, field of view = 64 × 64 mm, and velocity encoding (Venc) = 30-200 cm/s depending on the imaging section. For SPIV purposes, a laser light sheet was passed perpendicular to the axis of the phantom to illuminate the flowing fluorescent particles (Fig 1). A set of image pairs were captured using two cameras looking at the phantom at different angles and the fluid velocity was extracted using a cross-correlation scheme, yielding a nominal spatial resolution of 0.2 mm for the velocity data. The temporal resolution of pulsatile flow measurements was 25 ms, corresponding to 40 measurements per second.
منابع مشابه
Pressure gradient measurement using phase contrast (PC)-MRI in stenotic phantom models: Towards noninvasive quantification of fractional flow reserve in the coronary arteries
Background Fractional flow reserve (FFR) is an invasive diagnostic tool to evaluate the functional significance of an intermediate coronary stenosis by quantifying the pressure gradient (ΔP) across that stenosis [1]. Noninvasive ΔP measurement (ΔPMR) using phase-contrast (PC)-MRI in conjunction with Navier-Stokes (NS) equations has been attempted in large to medium size vessels [2-4], and recen...
متن کاملIn-Vitro Validation of Phase Contrast MRI in a Stenotic Phantom Under Steady Flow Using PIV
Introduction: Blood flow dynamics has an important role in atherosclerosis initiation, progression, and thrombosis leading to occlusive arterial diseases [1]. Since the development of Phase Contrast MRI (PC-MRI), it has been widely used to measure the velocity and flow in blood vessels. Accuracy of the PC-MRI velocity measurements in a 1.5T scanner has previously been evaluated using Laser Dopp...
متن کاملQuantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI.
PURPOSE Evaluate spiral three-dimensional (3D) phase contrast MRI for the assessment of turbulence and velocity in stenotic flow. METHODS A-stack-of-spirals 3D phase contrast MRI sequence was evaluated in vitro against a conventional Cartesian sequence. Measurements were made in a flow phantom with a 75% stenosis. Both spiral and Cartesian imaging were performed using different scan orientati...
متن کاملPhase contrast MRI with flow compensation view sharing.
PURPOSE To develop and evaluate a technique for accelerating phase contrast MRI (PC-MRI) acquisitions without significant compromise in flow quantification accuracy. METHODS PC-MRI is commonly acquired using interleaved flow-compensated (FC) and flow-encoded (FE) echoes. We hypothesized that FC data, which represent background phase, do not change significantly over time. Therefore, we propos...
متن کاملComputational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI.
BACKGROUND Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations. CFD provides arbitrarily high resolution, but its accuracy hinges on model ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2012