Altered Diastolic Flow Patterns and Kinetic Energy in Subtle Left Ventricular Remodeling and Dysfunction Detected by 4D Flow MRI

نویسندگان

  • Emil Svalbring
  • Alexandru Fredriksson
  • Jonatan Eriksson
  • Petter Dyverfeldt
  • Tino Ebbers
  • Ann F Bolger
  • Jan Engvall
  • Carl-Johan Carlhäll
چکیده

AIMS 4D flow magnetic resonance imaging (MRI) allows quantitative assessment of left ventricular (LV) function according to characteristics of the dynamic flow in the chamber. Marked abnormalities in flow components' volume and kinetic energy (KE) have previously been demonstrated in moderately dilated and depressed LV's compared to healthy subjects. We hypothesized that these 4D flow-based measures would detect even subtle LV dysfunction and remodeling. METHODS AND RESULTS We acquired 4D flow and morphological MRI data from 26 patients with chronic ischemic heart disease with New York Heart Association (NYHA) class I and II and with no to mild LV systolic dysfunction and remodeling, and from 10 healthy controls. A previously validated method was used to separate the LV end-diastolic volume (LVEDV) into functional components: direct flow, which passes directly to ejection, and non-ejecting flow, which remains in the LV for at least 1 cycle. The direct flow and non-ejecting flow proportions of end-diastolic volume and KE were assessed. The proportions of direct flow volume and KE fell with increasing LVEDV-index (LVEDVI) and LVESV-index (LVESVI) (direct flow volume r = -0.64 and r = -0.74, both P<0.001; direct flow KE r = -0.48, P = 0.013, and r = -0.56, P = 0.003). The proportions of non-ejecting flow volume and KE rose with increasing LVEDVI and LVESVI (non-ejecting flow volume: r = 0.67 and r = 0.76, both P<0.001; non-ejecting flow KE: r = 0.53, P = 0.005 and r = 0.52, P = 0.006). The proportion of direct flow volume correlated moderately to LVEF (r = 0.68, P < 0.001) and was higher in a sub-group of patients with LVEDVI >74 ml/m2 compared to patients with LVEDVI <74 ml/m2 and controls (both P<0.05). CONCLUSION Direct flow volume and KE proportions diminish with increased LV volumes, while non-ejecting flow proportions increase. A decrease in direct flow volume and KE at end-diastole proposes that alterations in these novel 4D flow-specific markers may detect LV dysfunction even in subtle or subclinical LV remodeling.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elevated energy loss in diastolic left ventricular inflow corresponds to an increase in kinetic energy in patients with a repaired atrioventricular septal defect: Quantification from 4D Flow MRI

Background Patients after atrioventricular septal defect (AVSD) repair may present abnormalities in valve morphology and subsequently develop altered left ventricular (LV) inflow patterns [1]. This may lead to energy loss and affect the kinetic energy in the LV. We aimed to quantify diastolic viscous energy loss and kinetic energy in the LV and to evaluate their association in AVSDrepaired pati...

متن کامل

4D flow MRI can detect subtle right ventricular dysfunction in primary left ventricular disease.

PURPOSE To investigate whether 4D flow magnetic resonance imaging (MRI) can detect subtle right ventricular (RV) dysfunction in primary left ventricular (LV) disease. MATERIALS AND METHODS 4D flow and morphological 3T MRI data were acquired in 22 patients with mild ischemic heart disease who were stratified into two groups based on LV end-diastolic volume index (EDVI): lower-LVEDVI and higher...

متن کامل

LEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION

In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...

متن کامل

4D flow CMR detects progressive improvement in ventricular function following cardioversion of atrial fibrillation

Background Atrial fibrillation (AF) causes impairment of cardiac hemodynamics and substantial cardiovascular morbidity. While AF is difficult to assess with cardiac gated CMR, successful electrical cardioversion of chronic AF is often followed by a transient period of atrial stunning where absence of mechanical atrial contraction, similar to that seen in AF, persists despite reinstitution of si...

متن کامل

Apical inflow is associated with increased energy loss during left ventricular diastole in patients with a repaired atrioventricular septal defect: a 4D flow MRI study

Background Patients after atrioventricular septal defect (AVSD) repair have aberrant atrioventricular valve morphology resulting in a disorganized left ventricular (LV) inflow [1] with an increased amount of inflow reaching the apical level of the LV and retaining there during the subsequent systole [1]. This may elevate energy loss in LV flow due to friction. We aimed to evaluate the associati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016