Improved diagnosis of orthopedic implant-associated infection by inoculation of sonication fluid into blood culture bottles.

نویسندگان

  • María Eugenia Portillo
  • Margarita Salvadó
  • Andrej Trampuz
  • Ana Siverio
  • Albert Alier
  • Lluisa Sorli
  • Santos Martínez
  • Daniel Pérez-Prieto
  • Juan P Horcajada
  • Lluis Puig-Verdie
چکیده

Sonication improved the diagnosis of orthopedic implant-associated infections (OIAI). We investigated the diagnostic performance of sonication fluid inoculated into blood culture bottles in comparison with that of intraoperative tissue and sonication fluid cultures. Consecutive patients with removed orthopedic hardware were prospectively included and classified as having OIAI or aseptic failure (AF) according to standardized criteria. The diagnostic procedure included the collection of five intraoperative tissue cultures and sonication of the removed device, followed by conventional culture of the sonication fluid. Cultures were incubated for 7 days (aerobic) or 14 days (anaerobic). In addition, 10 ml of sonication fluid was inoculated into each aerobic and anaerobic BacT/Alert FAN blood culture bottle and incubated in the automated blood culture system for 5 days. Of 75 included patients, 39 had OIAI and 36 AF. The sensitivity of sonication fluid inoculated into blood culture bottles (100%) was higher than that of conventional sonication fluid (87%; P = 0.05) or intraoperative tissue cultures (59%; P < 0.01). Previous antibiotic therapy reduced the culture sensitivity of conventional sonication fluid to 77% and that of intraoperative tissue to 55%, while it remained 100% for blood culture-inoculated sonication fluid. The time to positivity was shorter in blood culture-inoculated sonication fluid, with detection of 72% of microorganisms after 1 day of incubation, than for intraoperative tissue and conventional sonication fluid cultures, with detection of 18% and 28% of microorganisms, respectively. In conclusion, compared to conventional sonication fluid and intraoperative tissue cultures, sonication fluid inoculated into blood culture bottles improved the diagnosis of OIAI and considerably reduced the time to culture positivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Diagnosis of Orthopedic Implant-Associated Infections by Inoculation of Sonication

Fluid into Blood Culture Bottles 2 María Eugenia Portillo*, Margarita Salvadó, Andrej Trampuz, Ana Siverio, Albert Alier, Lluisa 3 Sorli, Santos Martínez, Daniel Pérez, Juan P. Horcajada, Lluis Puig 4 5 Microbiology Laboratory, Reference Laboratory of Catalunya, Barcelona, Spain 6 Center for Septic Surgery, Charité University Medicine Berlin, Berlin, Germany 7 Department of Orthopedic Surgery, ...

متن کامل

Improved diagnosis of infection associated with osteosynthesis by use of sonication of fracture fixation implants.

Previous studies have shown that sonication fluid cultures from removed orthopedic devices improved the microbiological diagnosis of orthopedic implant-associated infections; however, few of these investigations have applied sonication to the removed fracture fixation devices to evaluate its utility for the diagnosis of osteosynthesis-associated infection (OAI). We compared sonication fluid to ...

متن کامل

TITLE: Improved Diagnosis of Infection Associated to Osteosynthesis by Use of Sonication

20 Previous studies have shown that sonication-fluid cultures from removed devices improved the 21 microbiological diagnosis of orthopedic implant-associated infections; however, few of these 22 investigations have applied sonication to the removed fracture-fixation devices to evaluate its 23 utility as an adjunctive diagnostic tool for osteosynthesis-associated infection (OAI). We 24 compared ...

متن کامل

Sonication of explanted prosthesis combined with incubation in BD bactec bottles for pathogen-based diagnosis of prosthetic joint infection.

Prosthetic joint infection (PJI) is a rare but refractory complication of arthroplasty. Accurate identification of pathogens is a key step for successful treatment of PJI, which remains a challenge for clinicians and laboratory workers. We designed a combined culture method with sonication of implants and incubation in a BD Bactec system to improve the effectiveness of pathogen diagnosis in PJI...

متن کامل

Concentration of Sonication Fluid through Centrifugation Is Superior to Membrane Filtration for Microbial Diagnosis of Orthopedic Implant-Associated Infection.

Microbial identification of orthopedic implant-associated infections using sonication fluid (SF) submitted to a concentration step by membrane filtration (SMF) was compared with the standard centrifugation (SC) method. Among 33 retrieved infected implants, sonication identified microorganisms in 26 (78.8%). The sensitivity of SC was higher than that of SMF (78.8% versus 30.3%; P < 0.001).

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 53 5  شماره 

صفحات  -

تاریخ انتشار 2015