Patient-specific tracer activity in MPI SPECT: A hands-on approach

نویسندگان

  • J. D. van Dijk
  • P. L. Jager
  • J. P. Ottervanger
  • C. H. Slump
  • S. Knollema
  • J. A. van Dalen
چکیده

Previously, several studies have reported that a decreasing image quality in heavier patients in myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) can be compensated by using a body-weight-dependent tracer activity or scan time, as illustrated in Figure 1. Although we derived and validated a activity-scan-time formula for a conventional SPECT scanner, this formula cannot simply be used for all SPECT scanners. Differences in detector sensitivity, technical specifications such a collimator design and geometrical detector configuration, and acquisition and reconstruction settings limit the generalizability of the derived formula. Ideally, a tracer activity-scan-time formula should therefore be derived for each SPECT scanner using the method as described previously. However, this could be technically challenging and is time consuming. In this technical note, we therefore introduce, as a first-order approach, an alternative simplified method to obtain a body-weight-dependent protocol, which can easily be adopted in every day patient care. DERIVING A BODY-WEIGHT-DEPENDENT PROTOCOL

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TECHNOLOGIST CORNER Patient-specific tracer activity in MPI SPECT: A hands-on approach

Previously, several studies have reported that a decreasing image quality in heavier patients in myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) can be compensated by using a body-weight-dependent tracer activity or scan time, as illustrated in Figure 1. Although we derived and validated a activity-scan-time formula for a conventional SPECT scanner, t...

متن کامل

Diagnostic dilemma of ectopic pelvic kidney in planar skeletal and renal cortical scintigraphy resolved by SPECT/CT

We present a 55-year old male patient who was subjected to whole body skeletal scintigraphy for metastatic work up of urinary bladder cancer. Whole body 99mTc-methylene diphosphonate (MDP) skeletal scintigraphy was performed. That revealed no skeletal metastasis in the entire body skeleton and normally visualized left kidney with empty right renal fossa. Additionally tracer activity ...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using conventional SPECT.

BACKGROUND The decreasing image quality in heavier patients can be compensated by administration of a patient-specific dose in myocardial perfusion imaging (MPI) using a cadmium zinc telluride-based SPECT camera. Our aim was to determine if the same can be achieved when using a conventional SPECT camera. METHODS 148 patients underwent SPECT stress MPI using a fixed Tc-99m tetrofosmin tracer d...

متن کامل

Impact of Phase Analysis of Gated SPECT to Assessment of Left Ventricular Mechanical Dyssynchrony in Diabetic Patients with Normal MPI

Objective: Diabetes mellitus is an important cause of heart failure deployment of left ventricular mechanical dyssynchrony. Nuclear cardiology phase analysis is an accurate, repeatable and reproducible modality for measurement LV dyssynchrony .The aim of study was assessment of phase analysis parameter including Standard deviation (SD) and band width (BW) in diabetic patient with normal MPI com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2016