Accommodation microfluctuations and pupil size during sustained viewing of visual display terminals.

نویسندگان

  • L S Gray
  • B Gilmartin
  • B Winn
چکیده

Accommodation microfluctuations comprise two dominant frequencies; a low frequency component (LFC < or = 0.6 Hz) and a high frequency component (1.0 Hz < HFC < 2.1 Hz). In the present experiment we examine accommodation microfluctuations and steady-state pupil responses during sustained viewing of visual display terminals (VDTs). Steady-state accommodation and pupil responses were measured continuously and simultaneously using a modified Canon Autoref R-1 infra-red objective optometer and an Hamamatsu C3160 Perceptscope Video Area Analyser. Measurements were obtained at three time intervals (0, 10 and 20 min) during a 20 min reading task presented on five different displays. With the displays placed at 50 cm, the task was to locate and identify typographical errors in one of five sets of standard text. Five young visually-normal emmetropic subjects with a mean age of 22.5 +/- 3.0 years participated in the study. Two-way ANOVA revealed no significant variation in the magnitude of the accommodation microfluctuations with either display or task duration, nor was there any significant interaction between these two factors. There was no significant variation in mean pupil diameter with either display or task duration. These measures may have the potential to provide objective information about visual display quality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of modulating ocular depth of focus upon accommodation microfluctuations in myopic and emmetropic subjects

The magnitude of accommodation microfluctuations increases in emmetropic subjects viewing low luminance targets or viewing a target through small artificial pupils. Larger microfluctuations reported in myopia may result from an abnormally large depth of focus (DoF). The effect of modulating the size of the DoF has not been investigated in myopic subjects and may help to explain the cause of the...

متن کامل

Temporal dynamics and statistical characteristics of the microfluctuations of accommodation: dependence on the mean accommodative effort.

Microfluctuations of accommodation have been the subject of many studies. New technological developments now permit us to study the dynamics of the microfluctuations with unprecedented resolution and accuracy. We aim to characterise their temporal statistics for different levels of accommodative effort, using a custom-built aberrometer. We conducted 46 s long measurements on the dominant eye of...

متن کامل

The relationship between object spatial profile and accommodation microfluctuations in emmetropes and myopes.

The accommodation microfluctuations are thought to be used by the accommodation controller to obtain information about the direction and magnitude of the required response by monitoring changes in the contrast gradient of this image. The contrast gradient can be altered by presenting different spatial frequency (SF) targets to the eye. Twelve myopes (MYOs) and 12 emmetropes (EMMs) viewed sine a...

متن کامل

The effects of spatial frequency on the accommodation responses of myopes and emmetropes under various detection demands

The dependence of spatial frequency on accommodation has been investigated extensively. Recently, differences between myopes and emmetropes with respect to accommodative microfluctuations for high spatial frequency targets have been reported. Considering the diversity of accommodative responses (ARs) to sinusoidal gratings among subjects, this experiment was designed to analyze the contrast dep...

متن کامل

Development of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients

Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2000