Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS Application
نویسنده
چکیده
The new Agilent 7500cx with Octopole Reaction System (ORS) is capable of analyzing most typical environmental samples using only one mode of analysis: helium mode. For the first time, it is possible to analyze an entire environmental suite of elements, including Hg and the major elements such as Na, K, Ca, Mg, Al, and Fe, in less than 2.5 minutes per sample, under conditions that remove or reduce practically all matrix-based interferences.
منابع مشابه
Determination of Chromium, Selenium, and Molybdenum in Nutritional Products by ICP-MS Authors
An ICP-MS validated method for the rapid determination of chromium (Cr), selenium (Se), and molybdenum (Mo) in infant formula and adult nutritional products was successfully transferred from the Agilent 7500cx ICP-MS to the Agilent 7700x ICP-MS, and from lab 1 to lab 2, respectively. The key advantage of the method is that all samples can be analyzed using a single-cell gas mode (helium mode) t...
متن کاملRoHS/ELV Directives - Measurement of Heavy Metals Using ICP-MS Application
This application note describes a robust analytical method for the determination of heavy metals and substances regulated by the EU Restriction of Hazardous Substances/End of Life Vehicles (RoHS/ELV) directives. Based on the experience of Nihon Environmental Services Co., Ltd in Japan using an Agilent Technologies 7500c ORS (Octopole Reaction System) collision/reaction cell ICP-MS, this note su...
متن کاملBasic Performance of the Agilent 7700s ICP-MS for the Analysis of Semiconductor Samples
Agilent ICP-MS systems have become the benchmark for accurate low-level analysis of trace contaminants across a wide range of high-purity chemicals used in the semiconductor industry. As the first commercial ICP-MS to offer reliable and routine cool plasma operation, the Agilent 4500 Series ICP-MS set the standard for low level analysis of the previously problematic elements Na, K, Ca and Fe. B...
متن کاملPerformance of the Agilent 7900 ICP-MS with UHMI for high salt matrix analysis
Since the fi rst generation of commercial ICP-MS appeared on the market in the 1980’s, the technique has been adopted for trace elemental analysis across a wide range of industries and applications. The measurement of high matrix samples typical of environmental, clinical, food, nuclear and geological applications, however, remains challenging. When high total dissolved solids (TDS) samples are...
متن کاملRapid and Reliable Routine Analysis of Urine by Octopole Reaction Cell ICP-MS Application
The Agilent 7500c Inductively Coupled Plasma Mass Spectrometer (ICP-MS) was used for the fast, routine, and reliable analysis of 23 trace elements in urine. The complete method validation for all elements is described, including the evaluation of short-term and long-term stability, the analysis of different reference materials and the discussion of precision and accuracy in internal and externa...